Empire Comfort Systems BVD34FP30(F,L)N-2 Installation Instructions And Owner's Manual
Empire Comfort Systems BVD34FP30(F,L)N-2 Installation Instructions And Owner's Manual

Empire Comfort Systems BVD34FP30(F,L)N-2 Installation Instructions And Owner's Manual

B" vent zero clearance gas fireplace

Advertisement

Comfort Systems
"B" Vent Zero Clearance Gas Fireplace
Installer: Leave these instructions with the consumer.
Consumer: Retain these instructions for future use.
WARNING: If the information in this manual is not
property damage, personal injury or loss of life.
-
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
phone. Follow the gas supplier's instructions.
department.
- Installation and service must be performed by
supplier.

INSTALLATION INSTRUCTIONS

OWNER'S MANUAL
GAS-FIRED
NOT INTENDED FOR USE AS A PRIMARY HEAT
SOURCE. This appliance is tested and approved as
either supplemental room heat or as a decorative
appliance. It should not be factored as primary heat
in residential heating calculations.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
kit is used.
WARNING: If not installed, operated and maintained
in accordance with the manufacturer's instructions,
this product could expose you to substances in fuel or
from fuel combustion which can cause death or seri-
ous illness.
AND
B-VENT
GAS FIREPLACE
MODEL SERIES
MILLIVOLT
BVD34FP30(F,L)N-2
BVD36FP3(0,2)(F,L)N-1
BVP42FP30(F,L)N-1
BVP42FP32(F,L)N-3
DIRECT IGNITION
BVD34FP50(F,L)N-2
BVD36FP5(0,2)(F,L)N-1
BVP42FP50(F,L)N-1
BVP42FP52(F,L)N-3
UL FILE NO. MH45034
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BVD34FP30(F,L)N-2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Empire Comfort Systems BVD34FP30(F,L)N-2

  • Page 1: Installation Instructions

    INSTALLATION INSTRUCTIONS OWNER’S MANUAL Comfort Systems "B" Vent Zero Clearance Gas Fireplace B-VENT GAS FIREPLACE MODEL SERIES MILLIVOLT BVD34FP30(F,L)N-2 BVD36FP3(0,2)(F,L)N-1 BVP42FP30(F,L)N-1 BVP42FP32(F,L)N-3 DIRECT IGNITION BVD34FP50(F,L)N-2 BVD36FP5(0,2)(F,L)N-1 GAS-FIRED BVP42FP50(F,L)N-1 BVP42FP52(F,L)N-3 UL FILE NO. MH45034 Installer: Leave these instructions with the consumer.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Section Page Important Safety Information....................3 Safety Information for Users of LP Gas..................4 Introduction ..........................5 ..........................6 Fireplace Dimensions ........................6 Clearances ..........................7 Locating Fireplace........................7 Gas Supply ..........................8-9 Installation .........................10-11 Venting..........................12-13 Log Placement (BVD34 and BVD36) (5 Log Set) ..............14 Log Placement (BVP42) (4 Log Set) ..................15 Operating Instructions ......................16-17 Standing Pilot Wiring Diagram ....................18...
  • Page 3: Important Safety Information

    IMPORTANT SAFETY INFORMATION Before enclosing the vent pipe assembly, operate the appliance to ensure it is venting properly. tile or other combustible material other than wood placed on or near the appliance. or wood panel extending the full width and depth of proper operation.
  • Page 4: Safety Information For Users Of Lp Gas

    SAFETY INFORMATION FOR USERS OF LP GAS by point with the members of your household. Someday when and explosions. In its natural state, propane is odorless and there may not be a minute to lose, everyone’s safety will depend colorless. You may not know all the following safety precau- on knowing exactly what to do.
  • Page 5: Introduction

    INTRODUCTION Instructions to Installer shown in these instructions or use with a type of gas not shown on 1. Installer must leave instruction manual with owner after the rating plate is the responsibility of the person and company installation. making the change. Important All correspondence should refer to complete Model Number, Serial 3.
  • Page 6: Fireplace Dimensions

    SPECIFICATIONS BVD34FP BVD36FP BVP42FP Input Btu/hr Maximum 21,000 25,000 30,000 NOTE: Air shutter KWH (Maximum) settings are factory B-Vent Size 4" Diameter 6" Diameter 6" Diameter minimum settings. Some NAT. (Standard) venting configurations #44 (.086) #42 (.0935) #37 (.104) P-252 P-286 P-213 shutter adjustments for...
  • Page 7: Clearances

    CLEARANCES Mantel Chart (Figure 3) Clearance to Combustibles Back 0" (0 mm) Side 0" (0 mm) Floor 0" (0 mm) Top Stand-off 0" (0 mm) Top Framing Edge 1" (25mm) Figure 3 Figure 2 Combustible Material No greeting cards, stockings or ornamentation of any type should ignite combustibles.
  • Page 8: Gas Supply

    GAS SUPPLY The gas pipeline can be brought in through the right or left side of Installing a New Main Gas Cock the appliance. Consult the current National Fuel Gas Code, ANSI Each appliance should have its own manual gas cock. Z223.1 CAN/CGA-B149 (.1 or .2) installation code.
  • Page 9: Gas Supply

    GAS SUPPLY (CONT) Checking Manifold Pressures Both Propane and Natural gas valves have a built-in pressure regulator in the gas valve. Natural gas models will have a manifold pressure of approximately 3.5" w.c. (.871kPa) at the valve outlet with the inlet pressure to the valve from a minimum of 4.5" w.c. (1.120kPa) for the purpose of input adjustment to a maximum of 14.0"...
  • Page 10: Installation

    INSTALLATION Framing and Finishing A fresh air kit is available as an optional feature with this appliance. 1. Choose unit location. The fresh air kit helps to decrease the amount of room air taken by utilizing outside air for combustion. It is strongly recommended that it be installed.
  • Page 11 INSTALLATION (CONT) Combustible Surround Installation Minimum Framing Dimensions BVD34 BVD36 BVP42 "A" 35 3/4" 37 3/4" 37 3/4" (908mm) (959mm) (959mm) "B" 37 3/8" 39 3/8" 43 3/8" (949mm) (1,000mm) (1,102mm) "C" 14 3/8" 17 7/8" 17 7/8" (378mm) (454mm) (454mm) Note: Figure 11...
  • Page 12: Venting

    VENTING Note that for steep roof pitches, the vent height must be increased. In high wind conditions, nearby trees, adjoining roof lines, steep certain components before the appliance is completely positioned pitched roofs, and other similar factors can result in poor draft, and installed.
  • Page 13 VENTING (CONT) Model BVD34FP series uses a 4" B-Vent for operation. Models BVD36FP and BVP42FP series use a 6" B-Vent for operation. Clearances from which maximum vent runs can be determined. Always maintain minimum clearances or greater around the vent system. Do not pack air spaces with insulation or other material.
  • Page 14: Log Placement (Bvd34 And Bvd36) (5 Log Set)

    LOG PLACEMENT (5 LOG SET) Before you begin: if you are installing logs into the BVD34 or After handling logs, wash your hands gently with soap and water The positioning of the logs is critical to the safe and clean operation to Figure 16 and Figure 17 and corresponding WARNING when completing following log placement instructions.
  • Page 15: Log Placement (Bvp42) (4 Log Set)

    After handling logs, wash your hands gently with soap and water The positioning of logs is critical to safe and clean operation of refer to Figure 18, Figure 19, and Figure 20 and corresponding Figure 19 WARNING, when completing the following log placement WARNING: Failure to position the parts in accordance steps.
  • Page 16: Operating Instructions

    OPERATING INSTRUCTIONS 750 Millivolt System The OWNER should carefully read and follow these operating The standing pilot (750 millivolt system) is a continuous burning instructions at all times. Lower the door assembly to view the gas pilot. The pilot remains ON even when the main burner is OFF. When you ignite the pilot, the thermopile produces millivolts Initial Lighting (electrical current) which energizes the magnet in the gas valve.
  • Page 17 OPERATING INSTRUCTIONS (CONT) Electric (120 volt) Operated Remote Control, FREC STANDING PILOT OPERATING INSTRUCTIONS 15 foot length of wire that can be used to connect the valve to a wall switch (installer provided) or prior to installing the remote control optional equipment. remote control receiver.
  • Page 18: Standing Pilot Wiring Diagram

    STANDING PILOT WIRING DIAGRAM Figure 23 Page 18 26534-1-0610...
  • Page 19: Standing Pilot Lighting Instructions

    STANDING PILOT LIGHTING INSTRUCTIONS FOR YOUR SAFETY, READ BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.
  • Page 20: Standing Pilot Troubleshooting

    STANDING PILOT TROUBLESHOOTING With proper installation and maintenance, your new Gas Fireplace will provide years of trouble-free service. If you do experi- problems and the corrective action to be taken. 1. Spark ignitor will not light pilot after repeated triggering knob depressed in the PILOT position, with the pilot lit, and the switch in the OFF position.
  • Page 21: Standing Pilot Propane/Lp Gas Conversion

    1.65mm WARNING Dexen 10" w.c. R-7548 R-7548 R-7548 Regulator This conversion kit is to be installed by an Empire Comfort Systems, Gas Conversion 2139 2139 2139 )* in accordance with the Label manufacturer's instructions and all codes and requirements of the authority having jurisdiction.
  • Page 22 If the appliance has not been installed, or a warranty card has not been returned to Empire Comfort Systems, Inc., check off type of gas converted to on card (for reference once the unit is installed).
  • Page 23: Direct Ignition Wiring Diagram

    DIRECT IGNITION WIRING DIAGRAM LED CODES Steady ON Normal operation, power ON to control 2 Flashes 3 unsuccessful ignition trials 3 Flashes 4 Flashes Interrupt power for 5 seconds to reset control Steady Flash OPTIONAL REMOTE CONTROL (120V DIRECT IGNITION) Electric (120 volt) Operated Remote Control (FREC) 4.
  • Page 24: Direct Ignition Lighting Instructions

    DIRECT IGNITION LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE. A. BEFORE LIGHTING smell all around the appliance area department.
  • Page 25: Direct Ignition Troubleshooting

    DIRECT IGNITION TROUBLESHOOTING With proper installation and maintenance, your new Gas Fireplace will provide years of trouble-free service. If you do experience a the corrective action to be taken. Refer to page 24 for initial startup and GAS Line purge instructions. SYMPTOM CHECK ACTION...
  • Page 26: Direct Ignition Propane/Lp Gas Conversion

    DIRECT IGNITION PROPANE/LP GAS CONVERSION 1. Turn off the gas supply. 18. Loosen screw and attach a manometer or pressure gauge to 2. Turn off the electrical supply to the appliance if so the outlet pressure tap of the control valve. 19.
  • Page 27: Maintenance And Service

    MAINTENANCE AND SERVICE PLEASE NOTE It will be necessary to clean the glass periodically. During start-up It is normal for appliances fabricated of steel to give off condensation, which is normal, forms on the inside of the glass and some expansion and/or contraction noise during the start causes lint, dust and other airborne particles to cling to the glass up or cool down cycle.
  • Page 28: Bvd34 And Bvd36 Parts List

    BVD34 & BVD36 PARTS LIST INDEX PART NUMBER DESCRIPTION 19506 19506 19507 19507 TOP SHIELD 17301 17301 17301 17301 TOP STANDOFF (2 REQUIRED) 10554 10554 10554 10554 NAILING FLANGE (4 REQUIRED) M163 M163 M178 M178 FLUE OUTLET GASKET 19387 19387 19422 19422 FLUE OUTLET ASSEMBLY...
  • Page 29: Bvd34 And Bvd36 Parts View

    BVD34 & BVD36 PARTS VIEW 26534-1-0610 Page 29...
  • Page 30: Bvp42 Parts List

    BVP42 PARTS LIST INDEX PART PART NUMBER DESCRIPTION NUMBER 19508 19508 TOP SHIELD 17247 17247 TOP STANDOFF (2 REQUIRED) 10554 10554 NAILING FLANGE (4 REQUIRED) M178 M178 FLUE OUTLET GASKET 19422 19422 FLUE OUTLET ASSEMBLY 19398 19398 DOWNDRAFT BAFFLE 19467 19467 DRAFT BAFFLE R7053...
  • Page 31: Bvp42 Parts View

    BVP42 PARTS VIEW 26534-1-0610 Page 31...
  • Page 32: Fbb4 Optional Variable Speed Blower Installation Instructions

    FBB4 OPTIONAL VARIABLE SPEED BLOWER INSTALLATION Attention: Install blower assembly before connecting gas inlet supply line Position blower assembly behind gas valve, align notch on Note It is recommended that an ON/OFF wall switch be hold blower assembly in place. installed that will activate the power supply to the furnace 6.
  • Page 33 FBB4 OPTIONAL VARIABLE SPEED BLOWER INSTALLATION BLOWER ASSEMBLY COMPLETE FAN CONTROL SPEED CONTROL SPEED CONTROL Figure 26 Figure 27 26534-1-0610 Page 33...
  • Page 34: Junction Box Wiring Installation Instructions

    JUNCTION BOX WIRING INSTALLATION INSTRUCTIONS CAUTION: ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE WITH ALL MAIN POWER SUPPLY IS DISCONNECTED. THE APPLIANCE, WHEN INSTALLED, MUST BE ELECTRICALLY GROUNDED IN ACCORDANCE WITH LOCAL CODES OR, IN THE ABSENCE OF LOCAL CODES, WITH THE NATIONAL ELECTRICAL CODE ANSI/NFPA 70 (LATEST EDITION) A factory installed junction box is located on the lower right side of the fireplace.
  • Page 35: Optional Accessories

    OPTIONAL ACCESSORIES The following accessory parts can be obtained from your Empire Comfort Systems dealer. If you need additional information beyond what your dealer can furnish, contact Empire Comfort Systems Inc., Nine Eighteen Freeburg Ave., Belleville, Illinois 62220-2623. Accessory Description...
  • Page 36: Decorative Accessories

    DECORATIVE ACCESSORIES Decorative Louver Leaf Decorative Louver Mission Decorative Louver Arch Decorative Door Leaf Rectangle Decorative Door Mission Rectangle Decorative Frame Rectangle with hinges Decorative Door Plain Rectangle Decorative Frame Arch with hinges Decorative Door Leaf Arch Decorative Door Mission Arch Decorative Door Plain Arch STD Louvers 45 Deg Decorative Frame Arch without hinges...
  • Page 37: Master Parts Distributor List

    To Order Parts After the Warranty Period, please contact your dealer or one of the Master Parts Distributors listed below. This list grows from time to time. For the current list, please click on the Master Parts button at www.empirecomfort.com. for Heaters, Grills, and Fireplaces manufactured by Empire Comfort Systems Inc. Star-Fire Distributors...
  • Page 38: Quick Reference Guide

    Web Site: www.empirecomfort.com Empire Comfort Systems Inc. 918 Freeburg Ave. Belleville, IL 62220 Comfort Systems The Keystone "B" Vent Zero Clearance Gas Fireplace MILLIVOLT: BVD34FP30(F,L)N-2; BVD36FP30(F,L)N-1; BVP42FP30(F,L)N-1 DIRECT IGNITION: BVD34FP50(F,L)N-1; BVD36FP50(F,L)N-1; BVP42FP50(F,L)N-1 GAS-FIRED 37" 39" 43" 940mm 990mm 1092mm 34"...
  • Page 39 Web Site: www.empirecomfort.com Empire Comfort Systems Inc. 918 Freeburg Ave. Belleville, IL 62220 Comfort Systems The Keystone "B" Vent Zero Clearance Gas Fireplace MILLIVOLT: BVD34FP30(F,L)N-2; BVD36FP30(F,L)N-1; BVP42FP30(F,L)N-1 DIRECT IGNITION: BVD34FP50(F,L)N-1; BVD36FP50(F,L)N-1; BVP42FP50(F,L)N-1 GAS-FIRED Minimum Framing Dimensions BVD34 BVD36 BVP42 "A"...