General Information - Belling IHTK60 Users Manual & Installation Handbook

Table of Contents

Advertisement

General information

Installation should only be carried out by
a qualified installer or engineer.
Please keep to the following points most-
carefully;
Although every care has been taken to
ensure this appliance has no burrs, or
sharp edges, we recommend that you
wear protective gloves when install-
ing and moving this appliance. This will
prevent injury.
The hob should not be fitted above a
washing machine, a fridge or a freezer.
Wall surfaces above the work surface and
in the immediate vicinity of the cooking
hob must be heat resistant.
Laminated surfaces and the adhesive
used for fixing them must be heat resis-
tant in order to avoid any damage.
The space for air circulation, located
underneath and at the back of the hob
improves its reliability by ensuring that it
will cool down, efficiently.
Installations should be carried out in line
with the National Regulations applicable
with this product type.
Choosing your installation
Make sure that the air inlets through the
ventilator grids underneath the hob are
never blocked.
Installation above a unit with a
drawer or door
The Hob's air outlet is underneath work
surface. If necessary, remove the front
crosspiece of the unit to allow suitable
ventilation.
30mm
Worktop
INSTALLATION
Installation above an oven
Refer to the manufacturer's instructions
for clearances above the oven. We recom-
mend a 20mm gap between the bottom
of the hob and appliance, should the work
surface be less than 38mm deep.
5mm
In the case of a pyrolytic oven
If installing the hob above a pyrolytic
oven, additional provision for air circula-
tion / ventilation may be required. Due to
the excessive temperatures attained dur-
ing pyrolysis, using the hob at the same
time may cause the thermal safety device
within the hob to operate.
Hob
INSTALLATION ABOVE AN OVEN
We recommend that you install this
Worktop
Hob
appliance in a work top which is a
minimum 38mm deep.
The hob can be fitted into a work top
Oven
less than 38mm deep, but the 20mm
gap between hob base and appliance
or cabinet partition must be main-
tained.
INSTALLATION ABOVE A UNIT WITH
A DRAWER OR DOOR
Worktop
Hob
Partician
Partition
Worktop
oven or partition
25mm
25mm
Hob
20mm

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ih60

Table of Contents