gas and ceramic.
This helps reduce the risk of fire through
any misuse of the hob.
a
Approx Glass
Surface
Temperature
225ºC
265ºC
e
Note: The safety temperature control
of the pans is only possible with quality
flat bottomed pans suitable for induction
cooking; Poor quality pans can create
air gaps between the glass and the
+
=
pan, which affects the accuracy of the
temperature control.
Residual heat indicators
=
If glass surface is above 65ºC when the
cook zone is switched off an "H "will be
displayed in the cook zone display until
the glass surface drops below approx
63ºC.
This feature not only warns you against
hot surfaces but also indicates that there
is residual heat which can be used as
temporary warm zone.
The cook zone itself does not heat up,
but the ceramic glass does get hot
because of the hot pan conducting heat
back onto the hob glass.
Auto stand by
The Hob will automatically switch off if
USING THE HOB
b
c
d
Intelligent hob
saftey system
Cooking zone
switches
off the error
message "E2"
All cooking zones
are
switched off with
the error message
"E2"
f
g
h
left (with pan) on for an extended period
of time, see maximum running times
below.
Power Level
1
2
3
4
5
6
7
8
9
P (Power Boost)
Ensure you switch off the appropriate
cook zone individually or by the central
on/off key when you have finished
cooking, do not rely upon the automatic
pan detection system as your means of
switching "off" the appliance.
The appliance must never be discon-
nected from the mains supply during use
as this will seriously affect the safety and
performance, particularly in relation to
surface temperatures becoming hot and
component parts not working efficiently.
The cooling fan (if fitted) is designed to
run on after the cook zones have been
switched off.
This induction hob complies with the
applicable EMC and EMF standards.
Therefore it should not interfere with
other electronic units. Persons fitted with
a pacemaker or any other electrical
implant should clarify with their doctor or
the producer of the implant, whether
there implant is adequate and fail-safe.
Maximum
Operation Time
hours
8
6
5
5
4
1.5
1.5
1.5
1.5
Max 5mins