Clearances and dimensions – re-
quirements
1.
No shelf or overhang of combus-
tible material should be closer than
650mm above the hob.
2.
There must be a minimum clearance
of 50mm between the edges of the
hob and any side walls; this clearance
must be maintained up to 420mm
above the worktop.
3.
There must be a minimum clearance
of 50mm between the rear edge
of the hob and the rear wall. This
clearance must be maintained up to
650mm above the worktop.
4.
When installing an extractor hood
above the hob, refer to their Manu-
facturer's instructions.
Minimum distance
between carcasses must
be equal to width of hob
*
420mm min
50mm min
490mm
50mm Min
*
Minimum height to extractor
as recommend in extractor
instruction manual
INSTALLATION
50mm min between hob and rear wall
560mm
(>60mm to cut out aperture)
rear wall
50 mm
Cutout Required
Width
Depth
Clearance Required
Side Wall
Rear Wall
Fitting into worktop
Cut a hole in the work surface to the
required size. See table for relevant
dimensions.
A clearance of at least 50mm should be
maintained between the cutout and any
rear or side wall.
The worktop must be of heat-resistant
material or covered with heat-resistant
material.
560mm
490mm
50mm
50mm