Lp Gas Leaks - Winnebago Sunflyer Manual

Hide thumbs Also See for Sunflyer:
Table of Contents

Advertisement

SECTION 5
LP GAS SYSTEM
in place at all times. Only your dealer or a quali-
fied LP gas service should remove the regulator
cover for adjustments.
WARNING
Inspect the pressure regulator vent
hole periodically for blockage. If any
obstruction is apparent, have the regu-
lator serviced by your dealer or a qual-
ified LP gas service center.
LP gas regulators are installed with
the diaphragm vent facing downward.
Make sure that the regulator vent
always faces downward to minimize
vent obstruction which could result in
excessive pressure, causing a fire or
explosion.
Regulator freeze-ups are caused by the pres-
ence of moisture in fuel. This moisture will pass
through the cylinder valve and into the regulator
where it can freeze. Fuel producers, tank and bot-
tle manufacturers and LP gas dealers take every
precaution to reduce moisture, but sometimes
only a fraction of an ounce entering the tank can
cause problems. To help avoid the possibility of
freeze-up, always keep tank control valve closed
when not in use, even when tank is empty, to pre-
vent moisture from collecting on the inside.
If regulator freeze-up should occur, you may
attempt to thaw the regulator using a light bulb.
DO NOT USE AN OPEN FLAME OR HEAT
LAMP.
LPG PRESSURE REGULATOR
(COVER OPEN)
5-4
your LP gas dealer inject a small amount of dry
methyl alcohol in your tank (approximately one
once to 20 pounds or one pint to 100 gallons) to
help guard against regulator freeze-ups.
gas is being used for heating, it is possible to ex-
perience a loss of gas pressure. At first, this prob-
lem may appear to be caused by a regulator
freeze-up, but is actually caused by failure of the
liquid gas to vaporize as fast as it is needed. As
the temperature becomes colder, it is increasingly
harder for the liquid LP gas to vaporize. At the
same time, the demand for LP to produce heat in-
creases to the point where the system cannot
maintain production.
the consumption of gas where possible. Adjust-
ing the temperature on the gas/electric refrigera-
tor may be a first step. Using less hot water will
help as well.
hicle near the range area. If you smell gas within
the vehicle, quickly and carefully perform the
procedures listed.
LP GAS ALARM - See page 1-3.
Vent Hole
If moisture begins to cause problems, have
In very cold weather when a large volume of
The only solution to this problem is to reduce

LP GAS LEAKS

The following label has been placed in the ve-
IF YOU SMELL GAS
1.
Extinguish any open flames, pilot lights and all
smoking materials.
2.
Do not touch electrical switches.
3.
Shut off the gas supply at the tank valve(s) or gas
supply connection.
4.
Open doors and other ventilating openings.
5.
Leave the area until odor clears.
6.
Have the gas system checked and leakage source
corrected before using again.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sunflyer 34ySunflyer 35uSunflyer 36wSunflyer 36l