Compaq ProLiant ML570 Maintenance And Service Manual page 119

Hide thumbs Also See for ProLiant ML570:
Table of Contents

Advertisement

3-42 Compaq ProLiant ML570 Maintenance and Service Guide
Table 3-18
Array Diagnostic Utility (ADU) Error Messages
Message
Other controller
indicates different
cache size
RIS copies between
drives do not match
SCSI port X
Drive ID Y failed –
REPLACE (failure
message)
SCSI port X, Drive ID
Y firmware needs
upgrading
SCSI port X,
Drive ID Y has
exceeded
threshold(s)
continued
Description
The other controller in the
redundant controller configuration
has a different size array
accelerator.
The drives on this controller contain
copies of the RIS that do not match.
ADU detected a drive failure.
Firmware for the drive may cause
problems and should be upgraded.
The monitor and performance
threshold for this drive has been
violated.
Recommended Action
Make sure both controllers are using the same
capacity array accelerator.
The hard drives in the array do not have
matching configuration information. To remedy:
1.
Resolve all other errors encountered.
2.
Obtain the latest version of ADU, and then
rerun ADU.
3.
If unconfigured drives were added,
configure these drives using the Array
Configuration Utility (ACU). Once these
drives are configured, the error should be
resolved.
4.
If drives or arrays were moved, make sure
the movement adheres to the guidelines
listed in the documentation for the array
controller.
5.
If the error persists after completing steps
1-4, contact a Compaq authorized service
provider.
Correct the condition that caused the error, if
possible, or replace the drive.
Run Options ROMPaq Utility to upgrade the
drive's firmware to a later revision.
Verify and resolve the threshold that has been
violated.
continued

Advertisement

Table of Contents
loading

Table of Contents