Fans

The ProLiant ML570 server ships standard with two hot-plug system fans (one CPU and one
I/O) and three redundant, hot-plug drive fans. The two system fan baskets are designed to allow
for a redundant hot-plug fan in each basket. Figure 2-6 and Table 2-1 show the location of all
fans in the ProLiant ML570 server, including the fan name and primary function.
NOTE: Fans may continue to spin after a temporary failure occurs. Replace failed fans (amber LED) even
if spinning continues.
Figure 2-6. Hot-plug fan locations
Fan




,
,



Note: An amber fan LED indicates fan failure. A green fan LED indicates that the fan is working
properly. See "Hot-Plug Fan LED Indicators" in Chapter 4 for more information.
5
6
3
4
Table 2-1

Hot-Plug Fan Locations

Name
Primary Function
Hot-plug system fan
Primary CPU fan
Hot-plug system fan
Redundant CPU fan
Hot-plug system fan
Primary I/O fan
Hot-plug system fan
Redundant I/O fan
Hot-plug hard drive fan
Drive fans
Removal and Replacement Procedures 2-13
7
1
2
Area Cooled
Processors
Processors
System board
System board
Hard drives