Command
Get Trigger
Get Trigger Duration
Get Pre Exposure
Get Double Exposure
Get CC Integration
Command
Get Analog Offset
Get Analog Gain
Trigger Control
Syntax
Parm#1
String
returned
gtr
off|cc|et
s|f|d
gtd
gpe
gde
gci
off|on
Analog Amplifiers
Syntax
Parm#1
String
returned
gao
0|1|2
gag
0|1|2
187 of 216
LYNX Hardware User's Manual
Description
Returns the current trigger mode setting:
off = disabled
cc = CC1
et = external
s = standard
f = fast
d = double
i
Returns the current number of frames to be
transmitted after a trigger event has
occurred. The valid range is 1 to 249. A
value of 250 – 255 indicates that the camera
is free running.
i
Returns the current pre-exposure in
uSeconds.
i
Returns the current double exposure in
uSeconds.
Returns the current CC integration mode:
off = camera timing determines exposure
on = CC1 pulse width determines exposure
Description
i j
Returns the current analog offset for the
specified channel. The parameter indicates
the channel. If the parameter is 0, then both
channels are returned.
i j
Returns the current analog gain for the
specified channel. The parameter indicates
the channel. If the parameter is 0, then both
channels are returned.

Advertisement