Imperx LYNX User Manual page 182

High-resolution, fast, field pgradeable, programmable, 8/10/12 bit digital cameras
Hide thumbs Also See for LYNX:
Table of Contents

Advertisement

Command
Set Horizontal Window
Set Vertical Window
Set Horizontal Mode
Set Vertical Mode
Command
Set Shutter Time
Set Long Integration
Set Frame Rate
Set Frame Time
Area of Interest
Syntax
Parm#1
Parm#2 Description
x1
shw
svw
y1
shm
n|w|b|c
svm
n|w|b
Exposure Control
Syntax
Parm#1
Parm#2 Description
sst
off|i
sli
off|i
sfr
off|i
sft
off|i
182 of 216
LYNX Hardware User's Manual
x2
Sets the horizontal window. The first
parameter, x1, is the starting pixel number
and the second parameter, x2, is the ending
pixel number.
y2
Sets the vertical window. The first
parameter, y1, is the starting line number
and the second parameter, y2, is the ending
line number.
Sets the horizontal mode of operation:
n = normal
w = windowing
b = binning
c= center
Sets the vertical mode of operation:
n = normal
w = windowing
b = binning
Sets the shutter time:
off = disabled
i = shutter time in uSeconds
Sets the long integration time:
off = disabled
i = integration time in mSeconds
Sets the programmable frame rate:
off = disabled
i = frame rate in frames per second
Sets the programmable frame time:
off = disabled
i = frame time in uSeconds

Advertisement

Table of Contents
loading

Table of Contents