Imperx LYNX User Manual page 168

High-resolution, fast, field pgradeable, programmable, 8/10/12 bit digital cameras
Hide thumbs Also See for LYNX:
Table of Contents

Advertisement

COMMON CONTROLS and DISPLAYS
Taps - Selects the camera output format.
Sets the camera to a single output mode.
Single:
Sets the camera to a dual output mode
Dual:
Depth - Selects the output bit depth.
Sets the output to 8 bit
8 bit :
10 bit :
Sets the output to 10 bit
12 bit :
Sets the output to 12 bit
LUT/FFC - Enables the use of the built in look-up tables (LUT) or Flat
Field Correction table.
Off :
Disables the use of LUT.
Enables the use of LUT #1.
LUT 1:
Enables the use of LUT #2.
LUT 2:
Enables the use of Flat Field Correction table.
FFC:
FFC/LUT1: Enables the use of Flat Field Correction table and LUT #1
simultaneously.
When clicked on displays the current internal camera
Current
temperature.
Temperature
Read:
When enabled turns on temperature alarm monitoring. The
Temperature
user can enter the SET/RESET values.
Alarm:
When enabled turns on the image reversal feature.
Image
Reversal:
When enabled turns on the negative image feature.
Negative
Image:
When enabled turns on the noise correction feature.
Noise
Corr.:
When enabled turns on the defect correction feature.
Defect
Corr.:
Displays the current camera speed (it is not active in trigger
Speed
mode).
Window:
Displays the current camera exposure (it is not active in
Exposure
trigger mode).
Window:
LYNX Hardware User's Manual