Remove A Sensor - Interlogix ZeroWire Installation Manual

Wieless security & home automation
Hide thumbs Also See for ZeroWire:
Table of Contents

Advertisement

If you have a double-storey property, it is suggested the ZeroWire unit be installed on
the highest level for the best signal strength.
ZeroWire installed below ground level (e.g. basement) may have reduced range.
Movement / Passive Infra-Red (PIR) sensors should be installed to look over the
partition you want to protect. The path of an intruder should walk across the front of the
PIR. A PIR is less sensitive to an intruder walking directly towards it. Avoid pointing the
PIR at windows or heat sources as these may cause the PIR to operate incorrectly.
Reed switches should be installed across doors/windows where two surfaces open and
close. Place the sensor on the frame and the magnet on the door/window. Take care to
close the door / window and note any gap between the magnet and the sensor. If the
gap is large the sensor will always be in an open state and prevent you from arming /
disarming the system. A plastic spacer can be used to ensure the reed switch seals
correctly.
4. Use Menu 4 – 4 to test sensor signal level.
If signal is low, then move sensor to another location. Alternatively move your ZeroWire to
a more central location.

Remove a Sensor

Example: Remove sensor 8
MENU
1.
YOUR 4 OR 6 DIGIT INSTALLER CODE
2.
3.
4.
5.
8
MENU
6.
 
10
5
 
  
ENTER
 
2
 
2
 
ENTER
 
 
MENU
MENU
 
  
Select Sensor Configuration.
 
Enter your Installer code.
Select 2 to remove sensor or keyfob.
Select 2 to remove sensor.
Select the sensor number that needs to be removed.
Exit from Advanced system configuration.