SB-2-253-I
1
Or
Torque to
15-20 ft. lbs.
1
4
3
2
7
8
10
9
Fluid Inlet Nipple
3/8 NPS (M)
14
16 15
*Apply thread sealant (i.e. Loctite #242 med.
strength blue or equal) onto threads.
6
5
19
18
*
Torque to
20-25 ft. lbs.
11
12
13
17
25
Spreader Adjustment
Assembly
27
26
4
33
Air Inlet Nipple
* 24
1/4 NPS (M)
(Torque to 15 ft. lbs.)
23
21
20
+ Tapered edge faces out towards
U.H.M.W.
Poly. Piece
22

WARRANTY

This product is covered by DeVilbiss' 1 Year
Limited Warranty. See SB-1-000 which is available
upon request.
32
31
11
Detail Ref. No. 18 - Two piece packing
covered by U.S.Patent No. 5,209, 501.
packing nut.
Fluid Packing Nut
PTFE
+Inner PTFE Piece
Outer
Fluid Needle
Orient packing components as shown.
Tighten packing nut until needle starts to
drag in packing. Then loosen packing
nut just enough so the needle moves
freely.
28
29
30

Hide quick links: