Installation; Selecting A Site For The Switch - SignaMax 065-7405TB User Manual

Connectivity systems hardened ethernet switch
Table of Contents

Advertisement

Installation

This chapter gives step-by-step instructions about how to
install the switch:

Selecting a Site for the Switch

As with any electric device, you should place the switch
where it will not be subjected to extreme temperatures,
humidity, or electromagnetic interference. Specifically, the
site you select should meet the following requirements:
-
The ambient temperature should be between -40 to 75
degrees Celsius.
-
The relative humidity should be less than 95 percent,
non-condensing.
-
Surrounding electrical devices should not exceed the
electromagnetic field (RFC) standards.
- Make sure that the switch receives adequate ventilation.
Do not block the ventilation holes on each side of the
switch
-
The power outlet should be within 1.8 meters of the
switch.
Hardened Ethernet Switch
14