Clearance for Installing the Projector
Allow ample clearance between the projector and its surroundings as shown below.
The high temperature exhaust coming out of the device may be sucked into the device again.
Avoid installing the projector in a place where air movement from the HVAC is directed at the projector.
Heated air from the HVAC can be taken in by the projector's intake vent. If this happens, the temperature inside the
projector will rise too high causing the over-temperature protector to automatically turn off the projectors power.
Example 1 – If there are walls on both sides of the projector.
NOTE:
The drawing shows the proper clearance required for the front, back and top of the projector.
Example 2 – If there is a wall behind the projector.
NOTE:
The drawing shows the proper clearance required for the back, sides and top of the projector.
Example 3 – In the case of portrait projection.
NOTE:
• The drawing shows the proper clearance required for the front, back and top of the projector.
• See page
166
for an installation example on portrait projection.
20 cm/7.9" or greater
Lamp cover
Filter cover
(Intake vent)
13 cm/5.1" or greater
10 cm/3.9" or greater
Exhaust vent
13 cm/5.1" or greater