Axia iQ Installation & User Manual page 45

Console system
Table of Contents

Advertisement

»
Meter Source
»
Timer Mode
»
Timer Controls
»
Record Mode
»
Talk to backfeeds
»
Talk to Studio
»
Preview in HP
As usual, please remember to hit
are done to save your changes.
Record Mode
Record mode has four options:
»
Disabled (default)
»
Enabled
»
CR Ready
»
CR Ready with Auto Reset.
These options control the function of the Record key.
If any option but Disabled is selected, a unique Livewire
channel number must be assigned to the Logic port field.
When enabled, logic follows the Record Device
GPIO table found in the GPIO chapter of this manual.
CR Ready simply enables the first pin on the logic port
when the record button is pressed; CR Ready with Auto
Reset does the same, but the pin resets once a micro-
phone is turned on.
External Talk
If the console is installed in a Control Room where
the operator will not go "live" with a mic, this option
saves you from the need to assign the Operator Mic
source type to a fader for Talkback to Codecs or Phones.
Assign the appropriate source to External Talk, and with
no Operator mic loaded to a channel, the operator can
still engage Talk functions to backfeeds.
What's Next?
We have mentioned GPIO many times in the preced-
ing chapters. Join us in Chapter 5 to learn how to inter-
face the logic functions of your iQ console with the real
world.
when you
Apply
© 2014 Axia Audio - Rev 1.3.1