10. Battery connector (J300)

Fault symptoms
Customer
Mobile does not switch on
Exchange
battery connector
Service Repair Documentation
Level 2.5 - CFX65
Battery connector
Watch for oxidation and
damaged pads of the battery
connector
Check the status of the
not okay
battery connector visually
Use the resistor test
function of a multimeter to
not okay
check connection between
spring and soldered
contacts. Must be ~0Ω
22
GRT
No connection to GRT
not okay
okay
okay
okay
SCRAP
- check for twisted or
bent contacts
- check for dry joints
Level 2,5e repair
V1.0