4

Connector Battery

Fault Symptoms
Customer:
Mobile does not switch on
not okay
Exchange
Battery connector
Connector BATTERY
Use hot air blower to remove defective component. Avoid excessive heat! Watch surrounding components!
Resolder new component afterwards.
E-commerce order number:
E-commerce order name:
Soldering temperature:
IRIS Diagnose Code:
TI_Repair_L2.5l_A62_A65_A70_A75_R1.2.pdf
Battery connector
Problems
Watch for oxidation and
damaged pads of the battery
connector
Check the status of the
battery connector visually
Use the resistor test
function of a multimeter
to check connection
not okay
between spring
contacts and soldering
contacts. The value
must be ~0Ω
L36334-Z97-C213
CONNECTOR BATTERY 3-POL
240 - 255°C
(For A70 and A75 ~ 360°C Tip temp.)
13000 Battery/Mechanical Damage
Page
GRT:
No connection to GRT
not okay
okay
okay
okay
of
7
9
s Com
SCRAP
has to be
send separately to
WSC
- check for twisted or
bended contacts
- check for dry joints
Level 2 Repair
Release 1.2

Advertisement

loading

This manual is also suitable for:

A65A70A75