Battery Connector - Siemens CL75 Service Repair Documentation

Hide thumbs Also See for CL75:
Table of Contents

Advertisement

Company Confidential
Copyright 2005© Siemens AG

4. Battery Connector

Customer:
Mobile does not switch on
Not okay
Not okay
Exchange
battery
connector
Connector Battery
Use hot air blower to remove defective component. Avoid excessive heat! Watch surrounding
components!
E-commerce order number:
Soldering temperature:
IRIS Diagnose Code:
Service Repair Documentation
Level 2.5 – CL75
Battery connector
problems
Watch for oxidation and
damaged pad of the
battery connector
Okay
Check for dust inside the
battery connector
Check the status of battery
connector visually.
Use the resistor test
function of a multimeter to
check connection between
spring contacts and
soldering contacts. The
value must be ~0Ω
C39334-Z97-C486
240 – 255°C
91500 Functionality / Switch Off Problems / Battery Contacts Damage
Page 7 of 12
GRT:
No Support
SCRAP
Not okay
back to WSC
Not okay
Clean battery
connector
- Check for twisted or
bended contacts
- Check for dry joints
Level 2 Repair
Okay
Siemens Com
don't send