Download  Print this page

B To B Connector (j305) - Siemens CFX 65 Service Repair Documentation

Hide thumbs

Advertisement

Company Confidential
Copyright 2004© Siemens AG

1. B to B connector (J305)

Customer
No display but main board works
Camera and/ or earpiece does not work
Exchange
B to B connector
Connector board to board
Use soldering iron to remove defective component. Avoid excessive heat! Watch surrounding
components! Resolder new component afterwards.
E-commerce order number:
Soldering temperature:
IRIS diagnosis code:
Service Repair Documentation
Level 2.5 - CFX65
Fault symptoms
B to B connector
Watch for oxidation and damaged
pads of the B to B connectors
Check the status of the
not okay
B to B connector visually
Level 2,5e repair
L50634-Z97-C377
240 - 255°C
BA000 Accessories/ Camera
21000 Display/ Performance
22000 Display/ Background illumination
GRT
n/a
not okay
okay
okay
7
SCRAP
check for twisted or
-
bent contacts
- check for dry joints
V1.0

Advertisement

Table of Contents

   Also See for Siemens CFX 65

   Related Manuals for Siemens CFX 65

This manual is also suitable for:

Cfx 65

Comments to this Manuals

Symbols: 0
Latest comments: