Fuse (F300) - Siemens CFX 65 Service Repair Documentation

Hide thumbs Also See for CFX 65:
Table of Contents

Advertisement

Company Confidential
Copyright 2004© Siemens AG

11. Fuse (F300)

Fault symptoms
Customer
Battery charging does not work
Exchange
fuse
Service Repair Documentation
Level 2.5 - CFX65
Watch for oxidation and
damaged pads on the PCB
Check the status of the
not okay
fuse visually
Use the resistor test
function of a multimeter to
not okay
check connection between
soldered contacts.
Must be ~0Ω
24
GRT
n/a
Fuse
not okay
okay
okay
okay
SCRAP
- check for dry joints
Level 2,5e repair
V1.0

Advertisement

Table of Contents
loading

Table of Contents