11. Fuse (F300)

Fault symptoms
Customer
Battery charging does not work
Exchange
fuse
Service Repair Documentation
Level 2.5 - CFX65
Watch for oxidation and
damaged pads on the PCB
Check the status of the
not okay
fuse visually
Use the resistor test
function of a multimeter to
not okay
check connection between
soldered contacts.
Must be ~0Ω
24
GRT
n/a
Fuse
not okay
okay
okay
okay
SCRAP
- check for dry joints
Level 2,5e repair