7. I/O connector (J304)

Customer
Charging problems
Problems with external loudspeaker or microphone when
using a car kit
Problems with accessories connected to the I/O connector
Exchange
I/O connector
E-commerce order number:
Soldering temperature:
IRIS diagnosis code:
Service Repair Documentation
Level 2.5 - CFX65
Fault symptoms
I/O connector
Watch for oxidation and
damaged pads of the I/O
connector
Check for dust or dirt
inside the I/O connector
Check the status of the
not okay
I/O connector visually
Use the resistor test
function of a multimeter to
not okay
check connection between
spring and soldered
contacts. Must be ~0Ω
L50634-Z97-C375
240 - 255°C
46100 Interface/Charging connector/ Mechanical damage
GRT
No connection to GRT
okay
okay
okay
okay
17
not okay
SCRAP
not okay
Clean
I/O connector
- check for twisted or
bent contacts
- check for dry joints
Level 2,5e repair
V1.0