13. Camera connector

Fault symptoms
Customer
Camera malfunction
Exchange
camera connector
Service Repair Documentation
Level 2.5 - CFX65
Camera connector
Watch for oxidation and
damaged pads of the camera
connector
Check the status of the
not okay
camera connector visually
Use the resistor test
function of a multimeter to
not okay
check connection between
spring and soldered
contacts. Must be ~0Ω
GRT
n/a
okay
okay
okay
28
Exchange LCM
not okay
- check for twisted or
bent contacts
- check for dry joints
Exhange LCM
V1.0