Download Print this page

Firmware Upgrades - Extron electronics IN1606 Setup Manual

Scaling presentation switcher
Hide thumbs Also See for IN1606:

Advertisement

Use the Audio submenu to mute audio, set the audio
input format for the selected input, set analog audio gain,
set mic/line gain and phantom power, adjust mic/line and
program volume, and set audio output format.
Use the Advanced submenu to select a test pattern,
set the screen saver, turn on or off Auto-Image, set
the aspect ratio and auto memory settings, adjust
the overscan settings, and reset the device to factory
defaults.
Use the Communication submenu to view remote port
baud rate, the device MAC address, DHCP status, the
current IP address and subnet mask, and gateway.
NOTE:
Press and hold the Enter button for 10
seconds to edit settings in the Communication
submenu.
Use the Device Info submenu to view the device
name, firmware build, temperature, input and output information, and detected displays. This tab is read-only.
Internal Web Pages
The IN1606 can be configured, controlled, and operated
through the Ethernet port when connected to a LAN or WAN,
using a web browser. The browser displays the
factory-installed web pages, which provide a means of
configuring and operating the device. Enter the IP address
of the unit in the browser Address field to access the web
pages (see the IN1606 and IN1608 Series User Guide for more
details). The default IP address is 192.168.254.254. The default
subnet mask is 255.255.0.0.
Product Configuration Software
To configure the IN1606 using the Product Configuration
Software, install the software (available on the Extron website,
www.extron.com) to a PC connected to the IN1606 via
Ethernet, RS-232, or front panel USB Config port. After the
installation, start the program. For full instructions, press <F1>
or click the ? button and select Help File.

Firmware Upgrades

The onboard firmware of the IN1606 can be upgraded via the internal web pages or the Extron Firmware Loader program (available on the Extron
website, www.extron.com).
Output Rates
Output rates can be set using the OSD menu, the internal web pages, PCS, or SIS commands. The table below displays the most commonly used
resolutions and refresh rates and the corresponding SIS values. The command to set the output rate is
for the resolution and refresh rate combination as given in the example table below (see the IN1606 and IN1608 Series User Guide for the full list).
SIS Variable
Resolution
23.98 Hz
1024x768
1280x800
1440x900
1680x1050
1920x1200
720p
1080p
77
* = default
Basic SIS Command Table
The IN1606 can be configured with specific SIS commands via an RS-232, USB, or Ethernet connection. Use the Extron DataViewer utility or a
control system to send and receive SIS commands. The table on the next page lists a selection of SIS commands. For a full list of SIS commands
and variables, see the IN1606 and IN1608 Series User Guide, at www.extron.com.
X5$
for EDID or Output Resolution and Refresh Rate Combination (Where
24 Hz
25 Hz
68
78
79
Audio Input
Details
Format
None
Mutes all audio for selected input. Sets "No Audio" EDID.
Analog
Sets the selected input to analog (default for inputs 1 and 2).
Sets "No Audio" EDID.
LPCM-2Ch
Sets the selected input to LPCM-2Ch digital audio
(default for inputs 3-6). Sets 2Ch audio EDID.
Multi-Ch
Sets the selected input to Multi-Ch digital audio. Sets
Multi-Ch audio EDID.
LPCM-2Ch auto
Sets the selected input to prioritize digital audio. Analog
audio is passed when digital audio is not present. Sets 2Ch
audio EDID.
Multi-Ch auto
Sets the selected input to prioritize digital audio. Analog
audio is passed when digital audio is not present. Sets
Multi-Ch audio EDID.
29.97 Hz
30 Hz
50 Hz
19
31
52
59
63
69
70
71
80
81
82
EX5$
}
X5$
RATE
, where
is the SIS value
X5$
= 10 through 92)
59.94 Hz
60 Hz
75 Hz
20
32
53
60
64
72
73*
83
84
21
33
54
3

Advertisement

loading