Weighing Resolution; Timer Mode Setting; Espresso Mode Setting - acaia Coffee Scale Operation Manual

Table of Contents

Advertisement

Weighing Resolution [ rESoL ]
1. The default Weighing Resolution is set to [ dEFAUL ]: the division is 0.1g under weight of 1000g
and 0.5g from 1000g to 2000g.
button to switch the weighing resolution between [ dEFAUL ] and [
2. Press
3. When the Weighing Resolution is set to high, division will be 0.1g throughout the entire time
from 0g to 2000g.
4. Press and hold
option.
Timer Mode Settings [ t_nodE ]
After firmware 1.72, the default Timer mode is set to OFF.
1. OFF:The Timer mode is disabled, the scale will display two modes : Weighing Mode and Timer-
Weighing Mode.
2. ON: The Timer mode is turn on, the scale will display three modes: Weighing Mode, Timer Mode
and Timer-Weighing Mode.
Espresso Mode Settings [ E_nodE ]
In firmware 1.74, the default setting for Timer mode is set to OFF.
1. OFF:
Display format is 'm.ss.www'.
Note: m : minute, ss : second, www: weight.
The timer will stop at 9 minutes and 59 seconds.
When the weight is greater than 999, the second orange LED on the left will light on.
When the weight is negative, weight and negative sign will display alternatively.
2. ON:
Display format is 'ss.wwww'.
Note: s : second, wwww: weight.
When the value of the timer is greater than 59 seconds, the second orange LED on the left will
light on.
The timer will stop at 999 minutes and 59 seconds.

Chapter 4: Configuration
button for 1 second until [ SLEEP ] is shown on LED to confirm the selected
hiGh ].