Set Relay Activation Times - 23 and 24
Set the amount of time the relay will remain active between 1-250 seconds.
FACTORY SETTING: 10 Seconds
1. Press
2. Enter number of seconds Relay #1 will be active (1-250 Seconds)
3. Press
to save the data
EXAMPLE:
Sets Relay #1 to remain active for 35 seconds
1. Press
2. Enter number of seconds Relay #2 will be active (1-250 Seconds)
3. Press
to save the data
EXAMPLE:
Sets Relay #2 to remain active for 2 seconds
NOTE: If either relay is connected to a gate operator with a momentary contact closure, set the relay activation time for a
short period of time (i.e. 2 seconds). A longer activation time may cause the gate operator to repeatedly open and close
the gate until the activation time expires.
IMPORTANT NOTES: If you make an error during an entry, press the asterisk key ( ✱ ) to begin again.
The pound key (#) MUST be used to SAVE the data at the end of each programming step.
Time MUST be entered using a 24-Hour format (8:00 AM = 0800, 3:00 PM = 1500 etc.)
2 Short Beeps: Programming input is valid 1 Long Beep: Input is not valid.