Directed Electronics Python 1401 Installation Manual page 22

Remote start keyless entry
Hide thumbs Also See for Python 1401:
Table of Contents

Advertisement

Latched, reset with ignition: Similar to the latched output, this type of output
turns On the first time the Aux channel button is pressed, and turns Off the
next time the same button is pressed. This type of output additionally stops
and resets whenever the ignition is turned On and then Off.
30 seconds timed: The output sends a continuous signal for 30 seconds.
Note: Bitwriter® programs from 1 to 90 seconds.
H2/6
LIGHT BLUE
This wire produces a (-) 200mA output for progressive locks in which the driver
door unlocks first and the remaining locks will unlock with a second press of the
unlock button on the remote.
:
Note
This feature will need to be programmed "On" to function correctly (see
System Feature Menu #1, feature 8).
H2/7
GRAY/BLACK
Connect this wire to the wire in the vehicle that sends the signal to turn on the
WAIT-TO-START bulb in the dashboard. In most diesels the wire is negative
(ground turns on the bulb) and the GRAY/BLACK wire can be directly connected
to the wire in the vehicle. If the vehicle uses a positive wire (12V to turn on the
bulb) a relay must be used to change the polarity.
The system has a programmable onboard timer (See Feature menu#3, feature 9)
so it is not mandatory to connect to the wait-to-start wire in the vehicle.
22
Warning! Never use this wire to drive anything
but a relay or a low-current input, supplied out-
put is only 200mA. Connecting directly to a
solenoid, motor, or other high-current device
will cause the module to fail.
(-) 200mA 2ND UNLOCK OUTPUT
(-) DIESEL WAIT TO START INPUT