Symptoms Of High Or Low Blood Glucose; Specifications - Bayer HealthCare Contour next User Manual

Blood glucose monitoring system
Hide thumbs Also See for Contour next:
Table of Contents

Advertisement

Symptoms of High or Low Blood Glucose

You can better understand your test results by being aware
of the symptoms of high or low blood glucose. According
to the American Diabetes Association, some of the most
common symptoms are:
Low Blood Glucose
(Hypoglycemia):
• Shakiness
• Sweating
• Fast Heartbeat
• Blurred Vision
• Confusion
• Passing Out
• Seizure
• Irritability
• Extreme Hunger
• Dizziness
Ketones (Ketoacidosis):
• Shortness of Breath
• Nausea or Vomiting
• Very Dry Mouth
WARNING
If you are experiencing any of these symptoms,
test your blood glucose. If your test result is under
50 mg/dL or above 250 mg/dL, contact your health
care professional immediately.
For additional information and a complete list of symptoms,
contact your health care professional.
66
®
High Blood Glucose
(Hyperglycemia):
• Frequent Urination
• Excessive Thirst
• Blurred Vision
• Increased Fatigue
• Hunger

Specifications

Test Sample: Capillary whole blood
Test Result: Glucose measurements are reported as
plasma equivalents.
Sample Volume: 0.6 μL
Measuring Range: 20 - 600 mg/dL
Countdown Time: 5 seconds
Memory: Stores most recent 800 test results
Battery Type: Two 3-volt lithium batteries
(DL2032 or CR2032)
Battery Life: Approximately 1000 tests (1 yr. average use)
Operating Temperature Range: 41°-113°F
Humidity: 10 - 93% RH
Dimensions: 3.15" (H) x 2.09" (W) x 0.50" (T)
Weight: 1.6 oz. (45 grams)
Meter Life: 5 years
Sound Output: 55 to 80 dBA at a distance of 10 cm
Electromagnetic Compatibility (EMC): The C
meter complies with the electromagnetic requirements
specified in ISO 15197: 2003. Electromagnetic emissions
are low and unlikely to interfere with other nearby electronic
equipment, nor are emissions from nearby electronic
equipment likely to interfere with the C
Immunity to electrostatic discharge meets the requirements
of IEC 61000-4-2: 2008. It is advisable to avoid use of
electronic devices in very dry environments especially if
synthetic materials are present. The C
has been tested for radio frequency interference at the
frequency range and test levels specified by ISO 15197:
2003. To avoid radio frequency interference do not use the
C
N
meter near cellular or cordless telephones,
ONTOUR
EXT
walkie talkies, garage door openers, radio transmitters or
other electrical or electronic equipment that are sources of
electromagnetic radiation, as these may interfere with the
proper operation of the meter.
®
N
ONTOUR
EXT
N
.
ONTOUR
EXT
N
meter
ONTOUR
EXT
67