Symptoms Of High Or Low Blood Glucose - Bayer HealthCare CONTOUR XT User Manual

Blood glucose monitoring system
Table of Contents

Advertisement

Symptoms of High or Low Blood Glucose

You can better understand your test results by being aware
of the symptoms of high or low blood glucose.
According to the American Diabetes Association, some of
the most common symptoms are:
Low blood glucose
(Hypoglycaemia):
shakiness
sweating
fast heartbeat
blurred vision
confusion
passing out
seizure
irritability
extreme hunger
dizziness
Ketones (Ketoacidosis):
shortness of breath
nausea or vomiting
very dry mouth
Information For Safety
If you are experiencing any of these symptoms,
test your blood glucose. If your test result is under
2.8 mmol/L or above 13.9 mmol/L, contact your
healthcare professional immediately.
For additional information and a complete list of symptoms,
contact your healthcare professional.
38
C
®
XT meter C
ONTOUR
3
High blood glucose
(Hyperglycaemia):
frequent urination
excessive thirst
blurred vision
increased fatigue
hunger
®
N
test strips
ONTOUR
EXT
System Specifications
Test Sample:
Venous or capillary whole blood
Test Result:
Referenced to plasma/serum glucose
Sample Volume:
0.6 μL
Measuring Range:
0.6 - 33.3 mmol/L
Results:
5-second countdown
Memory Feature:
Stores most recent 480 test results
Battery Type:
Two 3-volt lithium batteries, 225 mAh capacity
(DL2032 or CR2032)
Battery Life:
Approximately 1000 tests (1 yr. average use)
Operating Temperature Range:
Humidity:
10 – 93% RH
Dimensions:
77 mm (H) x 57 mm (W) x 19 mm (T)
Weight:
47.5 grams (1.7 oz.)
Sound:
A beep sounds when the meter is turned on, a test strip is
inserted, when a test strip is filled with blood, or when a test
result appears on the display. Two beeps sound when the
meter turns off or to indicate an error. You will hear twenty
beeps when a programmed reminder sounds.
Electromagnetic Compatibility (EMC):
complies with the electromagnetic requirements specified in ISO
15197: 2003. Electromagnetic emissions are low and unlikely to
interfere with other nearby electronic equipment, nor are emissions
from nearby electronic equipment likely to interfere with the
C
XT. Immunity to electrostatic discharge meets the
ONTOUR
requirements of IEC 61000-4-2: 2008. It is advisable to avoid use of
electronic devices in very dry environments especially if synthetic
materials are present. The C
ONTOUR
radio frequency interference at the frequency range and test levels
specified by ISO 15197: 2003. To avoid radio frequency interfer-
ence do not use the C
XT meter near cellular or cordless
ONTOUR
telephones, walkie talkies, garage door openers, radio transmitters or
other electrical or electronic equipment that are sources of electro-
magnetic radiation, as these may interfere with the proper operation
of the meter.
The C
®
XT meter
ONTOUR
XT meter has been tested for
39