Bayer HealthCare CONTOUR NEXT LINK User Manual
Bayer HealthCare CONTOUR NEXT LINK User Manual

Bayer HealthCare CONTOUR NEXT LINK User Manual

Wireless blood glucose monitoring system
Hide thumbs Also See for CONTOUR NEXT LINK:

Advertisement

® ®
Wireless Blood Glucose
Monitoring System
12:00 PM
METER BG
5.2
mmol/L
®
Uses only C
®
N
blood glucose test strips from Bayer
ONTOUR
EXT
USER GUIDE

Advertisement

Table of Contents
loading

Summary of Contents for Bayer HealthCare CONTOUR NEXT LINK

  • Page 1 ® ® Wireless Blood Glucose Monitoring System 12:00 PM METER BG mmol/L ® Uses only C ® blood glucose test strips from Bayer ONTOUR USER GUIDE...
  • Page 2 INTENDED USE Talk to Your Health Care Professional • Before setting any Target ranges or High or Low Alerts on The C ® LINK wireless blood glucose monitoring system ONTOUR your meter. from Bayer (meter, test strips and control solution) is intended for self-testing by persons with diabetes to monitor glucose concentrations •...
  • Page 3 PRECAUTIONS • Use only approved cables or wall charger from the manufacturer or a 5V charger approved by a certified body such as UL, TUV or CSA. • Read your C ® LINK user guide, the M ® ONTOUR ICROLET lancing device package insert, your Medtronic device user guide and •...
  • Page 4: Table Of Contents

    Rechargeable Battery Table of Contents The C ® LINK meter from Bayer has a rechargeable battery. ONTOUR Your C ® LINK Wireless Blood Glucose ONTOUR You must charge your battery before you can use your meter and you Monitoring System from Bayer ........2 cannot do a blood sugar test while the battery is charging.
  • Page 5: Next

    Getting Started Your M ® 2 Lancing Device ICROLET Re-setting Handle The C ® LINK Wireless Blood ONTOUR Grip Indent Glucose Monitoring System from Bayer Release Button The C LINK wireless blood glucose monitoring ONTOUR system from Bayer works with C ®...
  • Page 6: Initial Setup

    Meter Overview • When your choice is highlighted, make a selection by pressing OK. Turning the Meter On or Off NOTE: Press and hold the L or M button to scroll • Press and hold the top Menu button to turn the meter on through the list faster.
  • Page 7 8. Scroll to Connect Devices and press UTILITIES MENU Set Language Alarm Clock ACT. Connect Devices These meter screen images are for Block illustration purposes only. Then scroll to Meters and press ACT. DEVICE OPTIONS 3. Press the M button to see LANGUAGE Meters Remotes...
  • Page 8 13. Select Review ID Press the Send Option SEND OPTIONS Always that is best for you. on your compatible Automatically send METER ID MENU Ask me Add ID results to the Pump? Medtronic device Your choice can be Delete ID Never to confirm that your changed later using...
  • Page 9 21. Press the L or M HIGH AND LOW ALERTS High and Low Alerts mmol/L button to select your High: 14.0 The High and Low Alert feature tells you when your test result Low Alert level. This is above or below the settings you choose. Results above High mmol/L Low: can be set between...
  • Page 10: Preparing The Lancing Device

    TARGET Examine product for missing, damaged, or broken parts. If the If AutoLog is ON, Accept Fasting: test strip bottle is open inside a new box of strips, do not use or Change the preset blood Accept those strips. Contact Bayer Customer Service for replacement 3.9 - 7.2 sugar range for Fasting, Change...
  • Page 11: Getting The Blood Drop - Fingertip Testing

    2. Loosen the round protective cap on the lancet by rotating 1. Remove a C ® test strip from ONTOUR it ¼ turn, but do not remove the bottle. Tightly close the bottle lid it. Always use M ® ICROLET immediately after you have removed the lancets for the best test strip.
  • Page 12: Test Results

    Test Results 3. Test immediately after Testing With AutoLog Off a good drop of blood TESTING... After applying blood to the has formed. test strip when AutoLog is turned OFF, your result will appear after the 5 second countdown. 4. Immediately touch the tip of the test strip to the drop of blood.
  • Page 13: Alternative Site Testing (Ast) - Palm

    YOUR RESULTS If Always was selected in Testing With AutoLog On mmol Send Options during Setup, AUTOLOG Send After you apply blood to the your result is automatically test strip, use the M to select Fasting sent to your pump. If Never Don’t Send Before Meal Fasting, Before Meal, After...
  • Page 14 IMPORTANT: Do not use AST under the following conditions: 4. Press the clear endcap • If you think your blood sugar is low firmly against the puncture • When blood sugar is changing rapidly (after a meal, insulin site and then press the blue dose, or exercise) release button.
  • Page 15 STRIP UNDERFILLED If the first blood drop is not enough, the meter will WARNING beep twice and display • Do not calculate a bolus based on an AST result. “ STRIP UNDERFILLED” and APPLY MORE BLOOD NOW • Do not calibrate your continuous glucose monitoring “APPLY MORE BLOOD NOW.”...
  • Page 16 WARNING: Potential Biohazard WARNING • Always dispose of test strip and lancet as medical You should consult your health care professional for waste or as advised by your health care professional. glucose values specific to your needs. All products that come in contact with human blood •...
  • Page 17: Control Solution Testing

    10:30 AM | 10/11 Control Solution Testing • If AutoLog is ON and you 14.0 mmol did not mark your result Reminder before the high or low alert WARNING High Blood Sugar appeared, select Notes. Notes Shake the control solution well before testing. ADD NOTES •...
  • Page 18 10:30 AM | 10/11 2. Hold the test strip with the 10. The meter shows the mmol grey square end facing AutoLog screen (if AutoLog is ON) but will sense control solution. Control Test 3. Insert the grey square The meter will count end of the test strip into down for 5 seconds and the control test result will display the test strip port until the...
  • Page 19: Autolog (Marking Your Results)

    Features CAUTION: Your C ®  LINK meter includes many ONTOUR • You may want to test with Send Options set to Never if testing features. you do not want to create a wireless signal (for example, if you have been asked to turn off all electronic devices AutoLog (Marking Your Results) in an aircraft).
  • Page 20 2. Press Start REMINDER Changing a Reminder Time Start to begin the COUNTDOWN 1. Press the L or M button to select the correct hours and Change countdown. The minutes (in 15-minute increments). preset time is Go Back REMINDER 2 hours or, if you CHANGE COUNTDOWN have changed it, 2.
  • Page 21: Notes

    Notes Using the Main Menu You may add notes to your test result that may help explain The Main Menu has three choices: Logbook, Trends, and results. Your notes will be saved in the Logbook. The option to Setup. Select one by pressing the button next to your choice. add a note is available only after a test result.
  • Page 22: Trends (Averages And Summaries)

    Trends (Averages and Summaries) Viewing Trends With AutoLog On The Trends feature displays your averages and your results as 1. Press and hold the top Menu button to turn the meter on. they compare to your Targets, over a period of time that you 2.
  • Page 23: Setup

    Setup PUMP OPTIONS Send Options You can view and change options on your meter and 4. Press Connection. Connection personalize it from the Setup Menu. Go Back 1. Press and hold the top Menu button to turn the meter on. 2.
  • Page 24 UTILITIES MENU 8. Scroll to Connect Devices and press 13. Select Review ID Alarm Clock ACT. on your compatible Connect Devices METER ID MENU Block Medtronic device Add ID Delete ID to confirm that your Then scroll to Meters and press ACT. DEVICE OPTIONS Review ID Meters...
  • Page 25: Test Reminders

    Send Options set. 16. The next screen confirms SEND OPTIONS Meter will ask you your Send Option 5. To change the current before sending results. Send is set to choice. Press OK. Change Send Option, press Always. Change. Go Back NOTE: If you want to disconnect the pump from the SEND OPTIONS meter, you do not need to take action on your meter.
  • Page 26: Date And Time

    REMINDER SETUP 5. After you have selected CHANGE COUNTDOWN hours, press OK. After you Pump Options 5. Reminder is now off. Reminder: Off have selected minutes, mins press OK. Date Reminder in: Date and Time 6. A confirmation screen Setting or Changing the Date Change appears and you can select Change or Done.
  • Page 27 Setting or Changing the Ti me Sound 1. Press and hold the top Menu button to turn the meter on. Turning the Sound On/Off 2. Press the button next to Setup. Sound is ON when you receive your meter. Some error messages and the Reminder bell will override the Sound SETUP Off setting.
  • Page 28 SETUP AutoLog is Off. 3. Press the M button to Sound A screen confirms highlight AutoLog. Press OK your choice. AutoLog: Off to select. Target NOTE: When you change your AutoLog setting to OFF, AUTOLOG you are asked to confirm your Target setting. 4.
  • Page 29 TARGET TARGET 5. Press the L or M button 5. Use the L or M button to Fasting to select your desired change each value of the Fasting Targets. Press OK - 10.0 Target. Press OK after each - 7.2 after each selection.
  • Page 30 HIGH AND LOW ALERTS TRENDS RANGE 6. Select 7, 14, 30 or 90 Day 6. Press the L or M button by using the M button and mmol/L 7 Day High: 13.9 to select your High and then press OK. 14 Day Low Alert.
  • Page 31: Transferring Data To Medtronic's Carelink

    Technical and Care Error Detection Displays • An error screen will always have an “E” with a number in the Transferring Data to Medtronic’s CareLink ® lower left corner of the display. Therapy Management Software Wrong Strip Inserted Repeat test with correct You can easily transfer blood Bayer strip.
  • Page 32 MENU As the battery is used, Rapid Charge Logbook the battery symbol on the If the battery is low when you plug in your meter, it will Rapid Trends screen gradually shows less Charge for about 1 minute. You can run a blood sugar test as Setup fill colour.
  • Page 33 Symptoms of High or Low Blood Sugar End of Meter Life/Battery Removal You can better understand your test results by being aware of NOTE: Carry out this process only when you no longer the symptoms of high or low blood sugar. Some of the most intend to use the meter.
  • Page 34: Technical Information

    Technical Information Precision Accuracy A repeatability study was conducted with the ®  LINK blood glucose monitoring system using ONTOUR The C ®  LINK blood glucose monitoring system ONTOUR five venous whole blood specimens with glucose levels from was tested in 100 capillary blood samples using 600 2.4 to 18.2 mmol/L.
  • Page 35 Comparison Options Service Information The C ® LINK system is designed for use with ONTOUR If you have a problem and none of the problem solving capillary whole blood. Comparison to a laboratory method messages on the meter help, contact Bayer Customer Service. must be done simultaneously with aliquots of the same sample.
  • Page 36 Symbols Used System Specifications The following symbols are used throughout the product labeling Test Sample: Capillary whole blood for the C ® LINK blood glucose monitoring system ONTOUR Test Result: Referenced to plasma/serum glucose (meter packaging and labeling, and reagent and control solution Sample Volume: 0.6 μL packaging and labeling).
  • Page 37: Caring For Your Meter

    Caring for Your Meter NOTE: If the meter is being operated by a second person who is providing testing assistance, the meter and CAUTION: Avoid exposing meter and test strips to lancing device should be disinfected prior to use by the excessive humidity, heat, cold, dust, or dirt.
  • Page 38 Disinfecting Your Lancing Device Supplies Needed for Disinfecting: • Germicidal wipes containing 0.55% sodium hypochlorite (bleach) • Paper towels Buttons USB Connector (under cap) Strip Port • Timing device 1. Before disinfecting, clean the lancing device as described Disinfecting Your Meter above in Cleaning Your Lancing Device.
  • Page 39: Warranty

    6. Longo D.L. et al. Harrison’s Principles of Internal Medicine, 18th Edition, 2011. http://www.accessmedicine.com 7. Data on file, Bayer HealthCare Diabetes Care. 8. Tietz Fundamentals of Clinical Chemistry, 5th Edition, Edited by Burtis CA and Ashwood ER, W. B. Saunders Co., Philadelphia, PA, 2001, p.
  • Page 40 (except as noted below). During the stated 5-year period, control solution. Bayer HealthCare shall, at no charge, replace a unit found 6. Bayer HealthCare makes no warranty of the performance to be defective with an equivalent or current version of the...
  • Page 41 Index Accuracy ......... Endcap ..........mg/dL (milligrams per decilitre) ..Target Ranges........Clear Endcap (for AST) ......3 With AutoLog Off .......49 Alerts ..........mmol/L (millimoles per litre)....Grey Endcap (for Fingertip Testing) ..3 With AutoLog On .......50 Battery ..........55 Notes ..........Error Displays ........
  • Page 43 Bayer Customer Service is available from 9 a.m. to 9 p.m. EST, 7 days a week at: 1-800-268-7200 www.bayerdiabetes.ca ®/TM Trademarks of Bayer HealthCare LLC, used under license by Bayer Inc. Bayer and Bayer Cross are registered trademarks of Bayer AG, used under license by Bayer Inc.