Drive motors

Removing
1. Raise the seat lift to its highest position (for
chairs without a seat lift, use the crank supplied)
see page 7.
2. Switch off the power using the control panel.
3. Remove the cover, see page 7. Move the
brake release lever fully forwards to facilitate
removal.
4. Put the circuit breaker to the "OFF" position,
see fig. 24.
5. Raise the relevant side of the chair using the
Permojack or raise the chair on blocks.
6. Remove the wheel, see Changing drive
wheels, page 9.
7. Disconnect the electrical connectors for the
motor and magnetic brake, see fig. 25.
8. Pull the cable sleeve forwards and take the
cable out through the slot in the cable
mounting. Unhook the brake release cable
from the magnetic brake, see fig. 26.
Fig.24. Circuit breaker/Battery isolator.
Fig.25. Magnetic brake and drive motor electrical
Fig.26. Brake release cable.
15
Drive motors
connectors.