FRU Replacements
2.8.1
Power Supply
Mellanox systems equipped with two replaceable power supply units work in a redundant config-
uration. Either unit may be extracted without bringing down the system.
To extract a power supply unit:
Remove the power cord from the power supply unit.
Step 1.
Grasping the handle with your hand, push the latch release with your thumb while pulling the
Step 2.
handle outward. As the power supply unit unseats, the power supply unit status LEDs will turn
off.
Remove the power supply unit.
Step 3.
25
Mellanox Technologies
Never run the system more than 5 minutes with an uncovered (open) PSU or fan slot.
Make sure that the power supply unit that you are NOT replacing is showing all green,
for both the power supply unit and System Status LEDs.
Power supply units have directional air flows similar to the fan module. The fan mod-
ule airflow must coincide with the airflow of all of the power supply units. If the power
supply unit airflow direction is different from the fan module airflow direction, the
's
system
internal temperature will be affected.
For power supply unit air flow direction, refer to Section 2.2 on page 8.