Fru Replacements; Power Supply - Mellanox Technologies SX67X0 Hardware User Manual

1u switch systems hardware
Table of Contents

Advertisement

Mellanox MLNX-OS Switch Management
Password:
Login as admin (default username is admin, password admin).
Step 3.
Once you get the CLI prompt, you are ready to use the system.
Step 4.
For additional information about MLNX-OS, refer to MLNX-OS User Manual located on Mellanox sup-
port web.
2.8

FRU Replacements

2.8.1

Power Supply

Mellanox systems equipped with two replaceable power supply units work in a redundant config-
uration. Either unit may be extracted without bringing down the system.
 To extract a power supply unit:
Remove the power cord from the power supply unit.
Step 1.
Grasping the handle with your hand, push the latch release with your thumb while pulling the
Step 2.
handle outward. As the power supply unit unseats, the power supply unit status LEDs will turn
off.
Remove the power supply unit.
Step 3.
25
Mellanox Technologies
Never run the system more than 5 minutes with an uncovered (open) PSU or fan slot.
Make sure that the power supply unit that you are NOT replacing is showing all green,
for both the power supply unit and System Status LEDs.
Power supply units have directional air flows similar to the fan module. The fan mod-
ule airflow must coincide with the airflow of all of the power supply units. If the power
supply unit airflow direction is different from the fan module airflow direction, the
's
system
internal temperature will be affected.
For power supply unit air flow direction, refer to Section 2.2 on page 8.
Installation

Advertisement

Table of Contents
loading

Table of Contents