Check Operation - KitchenAid 4KUIS185S Installation Instructions Manual

Automatic ice maker
Table of Contents

Advertisement

CUBELET CUTTER GRIDS
19mmx19mm
b
CUBE CUTTER GRID
l-114" x l-114" Cube Grid
(32 mm x 32 mm)
CHECK OPERATION
Start the unit by turning
the service switch to
"ON"
and opening the line water valve.
NOTE: Left is "OFF"-Middle
is "ON"--Right
is
"CLEAN."
In "CLEAN"
position, only the pump
operates.
Check condenser fan to make sure it is revolving.
Water will not enter pump pan until freezing plate
gets cold and machine goes into a harvest cycle.
Check for even water flow over freezing plate. Unit
must be level for proper operation.
Check for desired cube thickness
and after 24
hours adjust if necessary.
Maximum
ice yield
will be obtained with ice thickness at l/2" (12 mm)
to 518" (16 mm).
Replace grill.