FOR THE ELECTRICIAN
ELECTRICAL REQUIREMENTS
A 115 Volt, 60 Hz, AC only, 15 Amp fused electrical sup-
ply is required (time delay fuse or circuit breaker is
recommended).
It is recommended
that a separate
circuit, serving only this appliance,
be provided. DO
NOT use an extension
cord.
ELECTRICAL
GROUND IS REQUIRED
ON THIS
APPLIANCE.
RECOMMENDED
GROUNDING METHOD
DO NOT, UNDER ANY CIRCUMSTANCES,
REMOVE
THE POWER SUPPLY CORD GROUND PRONG.
For your personal safety, this appliance must be ground-
ed. This appliance is equipped with a power supply cord
having a 3-prong grounding plug. To minimize possible
shock hazard, the cord must be plugged into a mating
3-prong grounding
type wall receptacle,
grounded
in
accordance
with all governing codes and ordinances.
If a mating wall receptacle
is not available,
it is the
personal responsibility
and obligation
of the customer
to have a properly grounded
3-prong wall receptacle
installed by a qualified
electrician.
See Figure 6.
3-PRONG
GROUNDING
TYPE
II
II
WALL RECEPTACLE
-
POWER SUPPLY
FIGURE 6
ALTERNATE
GROUNDING METHOD
DO NOT, UNDER ANY CIRCUMSTANCES,
REMOVE
THE POWER SUPPLY CORD GROUND PRONG.
If changing and properly grounding the wall receptacle
is impossible and where local codes permit (consult your
5