FOR THE ELECTRICIAN
ELECTRICAL REQUIREMENTS
A 115 Volt,
60 Hz, AC only,
15 Amp fused electrical
supply
is
required
(time
delay
fuse or circuit
breaker
is recommended).
It is recommended
that
a separate
circuit,
serving
only
this
appliance,
be provided.
DO NOT use an extension
cord.
ELECTRICAL
GROUND
IS REOUIRED
ON THIS
APPLIANCE.
RECOMMENDED
GROUNDING MtrnOD
DO NOT, UNDER ANY CIRCUMSTANCES,
REMOVE
THE POWER SUPPLY CORD GROUND PRONG.
For
your
personal
safety,
this appliance
must
be grounded.
This appliance
is equipped
with
a power
supply
cord having a
3-prong
grounding
plug.
To minimize
possible
shock
hazard,
the
cord
must
be plugged
into
a mating
3.prong
grounding
type wall
receptacle,
grounded
in accordance
with
the National
Electrical
Code
and local
codes
and ordrnances.
If a mating
wall
receptacle
is not available,
it is the personal
responsibility
and obligation
of the customer
to have a properly
grounded
3-prong
wall
receptacle
installed
by a qualified
electrician.
See Figure
6.
3.PRONG
GROUNDING
TYPE
WALL
RECEPTACLE
GROUNDING
POWER
SUPPLY
FIGURE
6
ALTERNATE
GROUNDING MtrnOD
DO NOT, UNDER ANY CIRCUMSTANCES,
REMOVE
THE POWER SUPPLY CORD GROUND PRONG.
If changing
and properly
grounding
the wall recepta-
cle
IS
impossible
and
where
local
codes
permit