Gas Supply Requirements

Observe all governing codes and ordinances.
IMPORTANT: This installation must conform with all local
codes and ordinances. In the absence of local codes,
installation must conform with either the National Fuel Gas
Code, ANSI Z223.1/NFPA54, Natural Gas and Propane
Installation Code, CSA B149.1, Propane Storage And Handling
Code, B149.2, or the Standard for Recreational Vehicles, ANSI
A119.2/NFPA 1192 and CSA Z240 RV Series Recreational
Vehicle Code as applicable.
IMPORTANT: Grill must be connected to a regulated gas
supply. Refer to the model/serial rating plate for information on
the type of gas that can be used. If this information does not
agree with the type of gas available, check with your local gas
supplier.
Gas Conversion:
No attempt shall be made to convert the grill from the gas
specified on the model/serial rating plate for use with a different
gas type without consulting the serving gas supplier. The
conversion kit supplied with grill must be used. See "Gas
Conversions" section for instructions.
Gas Pressure Regulator
The gas pressure regulator supplied with this grill must be used.
The inlet (supply) pressure to the regulator should be as follows
for proper operation:
LP Gas:
Operating pressure: 11" WCP
Inlet (supply) pressure: 11" to 14" WCP
Natural Gas:
Operating pressure: 4" WCP
Inlet (supply) pressure: 7" to 14" WCP maximum.
Contact local gas supplier if you are not sure about the inlet
(supply) pressure.
Burner Requirements for High Altitude
Input ratings shown on the model/serial rating plate are for
elevations up to 609.6 m / 2,000 ft.
For elevations above 609.6 m / 2,000 ft, ratings are reduced at
a rate of 4% for each 304.8 m / 1,000 ft above sea level. Orifice
conversion is required. See "Assistance" section to order.
Gas Supply Line Pressure Testing
Testing above 3.5 kPa / 1/2 psi. or 14" WCP (gauge):
The grill and its individual shutoff valve must be disconnected
from the gas supply piping system during any pressure testing
of that system at test pressures greater than 3.5 kPa / 1/2 psi.
Testing below 3.5 kPa / 1/2 psi. or 14" WCP (gauge) or
lower:
The grill must be isolated from the gas supply piping system by
closing its individual manual shutoff valve during any pressure
testing of the gas supply piping system at test pressures equal
to or less than 3.5 kPa / 1/2 psi.

Gas Connection Requirements

9.07 kg (20lb) LP Gas Fuel Tank
This grill is equipped for use with a 9.07 kg (20lb) LP gas fuel
tank (fuel tank not supplied). A gas pressure regulator/hose
assembly is supplied.
Any brand of 9.07 kg (20lb) LP gas fuel tank is acceptable for
use with the grill, provided that it is compatible with the grill's
retention means (tank tray included).
It is also design-certified by CSA International for local LP gas
supply or for Natural gas with appropriate conversion.
A
A. Gas pressure regulator/hose assembly
The 9.07 kg (20lb) LP gas fuel tank must be mounted and
secured.
Door Style Tank Tray
1.
Open cabinet door.
2.
Slide the tank tray locking bracket counterclockwise 90º
and pull out the tray
A
A. Tank
22
tray
locking bracket