2004.5 Spectra Technology
Hydraulic pressure test can be performed at each of
the ports. Connect the AT pressure gauges to the
ports shown in the photos. ATF must be at operating
temperature.
Hydraulic Pressure Test with ATF at >176° F and
engine RPM at 2,500.
Measure the hydraulic pressure at each port, at each
shift position given above, and at 2500 RPM. Check
that the measured values are within the standard
valve range. If outside the range, refer to the A/T
TSB on KSIS.
Pressure given in PSI
Based upon Optima A/T
Powertrain
38