Error code
Description
959.30
Smart chip library flagged an invalid argument(s)
959.31
Smart chip library flagged an invalid device address
959.32
Failure to initialize physical interface
959.33
Unknown/unexpected Error
959.34
System smart chip Bus Busy Error
959.35
Transmission Error
959.36
Smart chip command is invalid due to unlocked device
status
959.37
Smart chip command is invalid due to locked device
status
959.38
Incremental counter id(s) are invalid
959.39
Invalid NV address
959.40
Invalid smart chip command
960.xx
RAM Memory Error—RAM soldered on the card is bad
961.xx
RAM Memory Error—optional DRAM is bad
964.xx
Download Emulation Cyclic Redundancy Check (CRC)
Error—checksum failure detected in the emulation
header or emulation file.
975.xx
Network Error—unrecognizable network port
976.xx
Network Error—unrecoverable software error in
network port
978.xx
Network Error—bad checksum while programming
network port
979.xx
Network Error—flash parts failed while programming
network port
Action
Replace the controller board. Go to
board removal" on page
Replace the controller board. Go to
board removal" on page
Replace the bad memory card.
1
Disable the Download Emulation.
2
Program the download emulation into the
firmware card again.
3
If the above steps do not resolve the problem,
then replace the firmware card and download
the emulation again.
Call the next level of support.