15. Apply Sealant to Base and Countertop
If the legs supplied with the dispenser are not used to raise the dispenser off the counter, the entire perimeter of the
base must be sealed at the countertop with silicone (or other food grade approved sealant) in order to comply with
NSF standards.
16. Brixing Concentrate
The following procedures describe how to adjust the water to concentrate ratio (brix) according to taste. Contact
the concentrate supplier for recommended brix ratios.
Unit comes with a water coil for dispensing water only. The push button valve to actuate is located on the left side of
the valve panel. Water solenoid assembly to control flow rate is mounted on the syrup pump platform. The flow rate
can be adjusted by turning adjusting screw on the regulator. Turning screw clockwise increases flow rate, turning
counter-clockwise reduces flow rate.
A. Remove the flavor strips above the dispense valves.
B. Sample the finished drink. Increase or decrease the water ratio by inserting a flat blade screwdriver into the
slot behind the flavor label and turning the water flow control screw clockwise (more water) or counter–
clockwise (less water) until the desired water to concentrate ratio is achieved. Repeat the procedure on the
remaining valves.
C. Replace the flavor strips.
NOTE: If the flow control does not respond, there may be debris caught between the internal
ceramic spool and sleeve. Try dislodging the debris by pressing the dispense switch several times
or by turning the flow control adjustment screw all the way in and out several times.
© 2003-2013, IMI Cornelius Inc.
- 7 -
Millennium II 4000 Installation Manual
Publication Number: 620919547INS