Error Codes -
The DigiSync slideout system is equipped
with onboard diagnostics capabilities. In the
event of a system failure the green LED on the
left side of the control panel will blink to display
several possible error codes. An error code will
not be displayed unless the "IN" or "OUT" con-
trol panel buttons has been pressed. For example,
the control panel will not display an error code
for low battery voltage unless you are trying to
extend or retract the room when low voltage is
present. Therefore it is a good idea if you have an
error code to write down which error code you
experienced to report it to your authorized ser-
vice center. This information will help the service
technician identify the cause of the problem that
you experienced.
When an error is detected, the green LED on
the left side of the control panel will blink. The
error code can be determined by counting the
number of flashes in between each pause. See the
Onboard Diagnostics Key below for details. The
error code may be cleared at any time by pressing
stop, or by allowing the system to 'time out' after
60 seconds. Once cleared, the operation can be
tried again. If the error code appears again, see
Semi-Manual Mode and or Crank Mode.
ERROR CODES
#Flashes
Problem
1
Unit Timed Out
3
Battery Voltage less
than 10 volts
4
Battery Voltage less
than 8 volts
5
Battery Voltage
greater than 18 volts
6
Stall on Rear Actua-
tor only
7
Stall on Front Actua-
tor only
8
Short Detect on Rear
Motor
2-20
Description
(ran for 60 sec with-
out reaching end of
stroke)
(detected when move
requested)
(detected during
move)
(detected when move
requested)
(Indicates obstruc-
tion at rear of room
or jam)
(Indicates obstruc-
tion at front of room
or jam)
(Rear motor is faulty
or wiring harness
faulty)
ERROR CODES
9
Short Detect on Front
Motor
10
No Current Detect on
Rear Motor
11
No Current Detect on
Front Motor
12
No Encoder Signal
detected on Rear
Actuator
13
No Encoder Signal
detected on Front
Actuator
14
Rear Actuator did not
re-sync with Front
Actuator within 5
seconds
15
Front Actuator did
not re-sync with Rear
Actuator within 5
seconds
Note: Manual Mode and corresponding Front and Rear Actuator
locations
Front Actuator: Retract/In button
Rear Actuator: Extend/Out button
See your dealer for service of the slideout
system before using again.
Further Information
See the Kwikee DigiSync Slideout Room
operating guide included in your Owner's Info-
Case for further instructions and troubleshooting
information.
(Front motor is faulty
or wiring harness
faulty)
(Rear motor is faulty
or wiring harness
faulty)
(Front motor is faulty
or wiring harness
faulty)
(Faulty encoder/har-
ness)
(Faulty encoder/har-
ness)