FocalPoint L23 CHESHIRE Installation And User Instructions Manual

FocalPoint L23 CHESHIRE Installation And User Instructions Manual

Flueless gas fire

Advertisement

L23 CHESHIRE
P23 MONET TRIO
P23 ENIGMA
FLUELESS GAS FIRE
INSTALLATION AND USER INSTRUCTIONS
All instructions must be handed to user for safekeeping
Revision A - 03/08
Country(s) of destination - GB/IE
Focal Point Fires plc, Christchurch, Dorset BH23 2BT
Tel: 01202 499330
Fax: 01202 499326
www.focalpointfires.co.uk
e-mail: sales@focalpointfires.co.uk

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the L23 CHESHIRE and is the answer not in the manual?

Questions and answers

Summary of Contents for FocalPoint L23 CHESHIRE

  • Page 1 L23 CHESHIRE P23 MONET TRIO P23 ENIGMA FLUELESS GAS FIRE INSTALLATION AND USER INSTRUCTIONS All instructions must be handed to user for safekeeping Revision A - 03/08 Country(s) of destination - GB/IE Focal Point Fires plc, Christchurch, Dorset BH23 2BT...
  • Page 2 L23 Cheshire P23 Enigma silver glass P23 Monet trio...
  • Page 3: Installation Instructions

    INSTALLATION INSTRUCTIONS Preliminary Notes Before Installation This appliance is a high efficiency, flueless, flame effect gas fire. It provides radiant and con- vected warmth both efficiently and safely utilising the latest type catalytic convertor burner technology. The appliance incorporates a combustion monitoring system (Oxygen Depletion System). It must not be adjusted or put out of operation.
  • Page 4: Table Of Contents

    Section Contents Page No. Section Contents Page No. Important Notes Testing and Commissioning Appliance Data Operating the Appliance Installation Requirements Spark Failure 3.1 Room Sizing Setting pressure Site Requirements Fitting the Decorative Frame 4.1 Ventilation Briefing the customer Unpacking the Appliance 10.0 Servicing 5.1 Component Checklist...
  • Page 5: Appliance Data

    APPLIANCE DATA L23 Models P23 Models Gas Group G20 Natural Gas CAT I2H G20 Natural Gas CAT I2H Inlet Pressure 20 mbar (+/- 2.0mbar) 20 mbar (+/- 2.0mbar) Max Energy Input Gross 2.0 kW Gross 2.0 kW 1.8 kW 1.8 kW Max Gas Rate 0.20 m3/h 0.20 m3/h...
  • Page 6: Ventilation

    SITE REQUIREMENTS (continued) Clearances to non-combustibles Non combustible surfaces are defined as brick, metal, marble, concrete etc. and also a number of man-made materials impervious to flame. If in doubt refer to the material manufacturer for further information before pro- ceeding with installation.
  • Page 7: Unpacking The Appliance

    DESCRIPTION Firebox and burner assembly Set of manufacturers instructions Decorative black glass facia assembly (L23 Cheshire models) Decorative metal facia panel in a variety of colours (P23 Monet trio models) Decorative silver glass facia panel (P23 Enigma models) Decotaive metal corner columns (P23 Enigma models)
  • Page 8: Fixing The Appliance

    A fitting template is sup- plied to assist with this. • For L23 Cheshire models : Mark the positions shown as “Gas model L23G” on the wall. • For P23 Monet trio and P23 Enigma models : Mark the positions shown as “Gas model P23G”...
  • Page 9: Testing And Commissioning

    TESTING AND COMMISSIONING Turn on and test the gas supply up to the fire for any leaks, in accordance with the current edition of BS6891. OPERATING THE APPLIANCE The pilot is visible behind the left hand side of the burner. The control knob is located on the lower right hand side of the outer ‘OFF’...
  • Page 10: Fitting The Decorative Frame

    FITTING THE DECORATIVE FRAME ASSEMBLY P23 Monet Trio models : P23 Monet Trio models The appliance is supplied with a selection of differently couloured decorative frames. Remove the chosen decorative frame assem- from any protective packaging, and remove any protective film that may be pres- ent on the frame.
  • Page 11: Briefing The Customer

    BRIEFING THE CUSTOMER All instructions must be handed to the user for safekeeping. Show the customer how to light and control the fire. After commissioning the appliance, the customer should be instructed on the safe use of the appliance and the need for regular servicing.
  • Page 12: Pilot Assembly

    10.2 PILOT ASSEMBLY Clean the pilot assembly with a soft brush and blow through. Check the aeration holes are free of any dirt or lint. Clean thoroughly internally, the connection can be removed from the base of the pilot unit using two span- ners to make cleaning easier.
  • Page 13: Troubleshooting Guide

    11.0 TROUBLESHOOTING GUIDE Fire sparks but pilot does not light No gas to fire, check isolators are open. Pipe work blockage, clean out. Air not fully purged, re purge supply or wait longer. Spark earthing to metal work, reset gap correctly. Blocked pilot, clean out internally.
  • Page 14: User Instructions

    USER INSTRUCTIONS Section Content Page No Important Notes Clearances to Combustibles Ventilation & Room Size Operating Instructions Combustion Monitoring System Cleaning Servicing List of Replacement Parts IMPORTANT NOTES The installation and Servicing of this fire MUST only be carried out by a competent person (such as a CORGI registered fitter) in accordance with the Gas Safety (Installation and Use) Regulations 1998, the relevant British Standards, Codes of Practice, the Building Regulations and the manufacturer's instructions.
  • Page 15: Clearances To Combustibles

    CLEARANCES TO COMBUSTIBLES Clearances to combustible materials Combustible materials are defined as wood, fabrics, or other materials likely to combust if exposed to flame. Generally, any material, which is likely to discolour, melt or misshape when exposed to moderate heat, should be considered as a combustible material or surface.
  • Page 16: Operating Instructions

    VENTILATION AND ROOM SIZE (continued) The room size should be a minimum of 23m 3 (e.g. 10’1” x 10’1” x 8’) to allow adequate circulation of air and ensure the correct operation of the fire. This volume may include adjacent spaces but these spaces must not be separated by a door.

This manual is also suitable for:

P23 monet trioP23 enigmaL23 black

Table of Contents