Information Submenu
Menu Structure
Info
Positive Watts Consumed
A read only indication of power consumed by the card from the frames +12V rail.
Negative Watts Consumed
A read only indication of power consumed by the card from the frames +-7.5V rail.
Software Release Number
A read only indication of the software release number. A higher number is newer release of software.
Software Build Number
A read only indication of the software build number. Software build number is an internal indicator
used by Cobalt engineers to differentiate different software builds.
Factory Default Settings
The factory default settings are as follows
1) The proc module is enabled, but all parameters are set to not change the video
2) The audio mapping is for simultaneous embedding and de-embedding. Discrete AES inputs 1-16
are mapped to embedded audio outputs 1-16. Embedded audio inputs 1-16 are mapped to discrete
AES outputs 1-16
3) Audio gain is set to 0dB and polarity is set to normal on all channels.
4) The Frame Sync is disabled, reference 1 or 2 must be chosen to enable the frame sync.
Page 18 of 27
+POW
-POW
SWR#
SWB#
Parameter Type
Positive Watts Consumed
Negative Watts Consumed
Software Release Number
Software Build Number
9035 Owner's Manual • • • • (V 1.0.9)