High-Pressure Hose And Spray Gun; Connection To The Mains; Cleaning Preserving Agent When Starting-Up Of Operation Initially; Ventilate Unit (Hydraulic System) If The Sound Of The Inlet Valve Is Not Audible - WAGNER Super Finish 27 Operating Manual

Airless high-pressure spraying unit
Hide thumbs Also See for Super Finish 27:
Table of Contents

Advertisement

Pay attention to the fact that the red inlet (2) is inserted into
the coating material inlet.
3.
Screw the upper hopper (3) onto the coating material inlet
(4).
4.
Hang the return pipe (5) into the upper hopper.
5.
Screw the union nut (6) on the return pipe (5) onto the
connection (7).
5
6
7
1
4.3

hIgh-preSSure hoSe and Spray gun

1.
Screw the high-pressure hose (fig. 8, item 1) onto the hose
connection (2).
2.
Screw the spray gun (3) with selected tip onto the high-
pressure hose.
3.
Tighten the union nut on high-pressure hose so that no
coating material escapes.
3
1
2
Super Finish 27 • 31
GB
4.4

connectIon to the maInS

Attention
Before connection to the mains, pay attention to the fact
that the mains voltage agrees with the information on
the makers' name plate on the rear of the unit.
The green control lamp will light up as soon as the mains plug
has been connected.
4.5
3
cleanIng preServIng agent when
StartIng-up oF operatIon InItIally
2
1.
unit with suction system
4
Submerge suction pipe into a vessel filled with a suitable
cleaning agent
2.
unit with upper hopper
Fill suitable cleaning agent into the upper hopper.
3.
Set multifunction switch (fig. 9, item 1) to
circulation); the unit commences to run. Turn pressure
regulation knob (2) to the right until stop.
4.
Wait until the cleaning agent flows out at the re-turn pipe.
5.
Set multifunction switch (1) to
of spray gun.
6.
Spray cleaning agent from the unit into an open collection
container.
1
4.6
ventIlate unIt (hydraulIc SyStem) IF the
Sound oF the Inlet valve IS not audIble
1.
Turn pressure regulating knob (fig. 10, item 1)
revolutions to the left.
2.
Set multifunction switch (2) to
hydraulic system is ventilated. Leave the unit on for two to
three minutes.
3.
Then turn the pressure regulating knob (1) to the
stop. Sound of the inlet valve is audible.
4.
If not, repeat points 1 and 3.
The connection must take place through a
correctly earthed two-pole and-earth socket
outlet.
(spray). Pull trigger guard
Starting operation
(ON–
2
three
(ON – circulation). The
right until
31

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Super finish 31

Table of Contents