1.- WARNING
Please read these instructions before installing or using this appliance for the first time.
The warranty of the heater will not cover any damage caused by non observance of any of these instructions.
This guide must be kept and given to any new owner.
Please check that the voltage in the rating label fits the power supply.
Any reinstallation should be carried out by trained personnel.
The use of these heaters is forbidden in any area where there is a presence of gases, explosives or inflammable objects.
DO NOT USE THIS HEATER TO DRY CLOTHES.
The surfaces of this heater can be hot, so young children should not be left unsupervised in the vicinity of the heater.
Neither the connecting cable nor any other object must come into contact with the hot unit.
Do not cover this heater at any time.
The air outlet at the top of the thermal radiator and the air inlet at the bottom are provided to ensure the most efficient operation of the
appliance. They also protect the heater from overheating; therefore, it is essential that at no time are they covered.
This heater should be switched off at the isolating switch before any repair work is carried out.
The thermal radiator should not be installed just below an electrical socket.
The appliance must be installed in such a way that it is impossible for anyone using a bath or shower, to touch the controls.
The installation must be carried out in accordance with the current electrical regulations.
The heater is fitted with a flexible cable size 3 x 1.00 mm2 for electrical connection. It may be used to connect the heater to the fixed wiring of
the premised through a suitable connection box positioned adjacent to the heater.
The supply circuit to the heater must incorporate a double pole isolating switch having a contact separation of at least 3 mm.
If the flexible power cable for this unit is damaged, it may only be replaced by a repair workshop recognised by the manufacturer, as special
tools are necessary.
This appliance must be earthed.
All models are supplied with an electrical interrupt cut-out. This will switch off the heater if, for any reason, it overheats. Should the cut-out
operate, turn the heater off and remove the cause for the overheating. The cut-out will be reset automatically.
The presence of air particles of smoke, dust and other pollutants could, in time, discolour the walls and surfaces around the heater.
This heater is filled with a precise quantity of special oil. Repairs requiring the opening of the oil container are only to be made by the
manufacturer or his service agent who should be contacted if there is an oil leakage.
Regulations concerning the disposal of oil when scrapping the appliance have to be followed.
Modelo
RF4P
RF6P
TYPE
MODULES
4
W (cm)
41.5
57.5
D (cm)
H (cm)
WEIGHT (kg)
9.5
13.5
INPUT
500W
750W
VOLTAGE

2.- INSTRUCTIONS ON INSTALLATION

- Open the carton at the indicated side. The screws are in the accessories bag. Turn the carton upside down to allow the heater to stand. Check
that it is the correct model and that it is in good condition.
- To obtain optimum performances it is necessary to maintain a minimum clearance of 15 cm between the radiator and any inflammable material
as furniture, curtains etc. See figure .

INSTALLATION INSTRUCTIONS

RF8P
RF10P
RF12P
Manual - Thermostat only
6
8
10
12
73.5
89.5
105.5
17.5
21.5
25.5
1000W
1250W
1500W
Closest
object to
the left
end
minimum15cm
minimum 10cm
RF14P
RF4E
RF6E
14
4
6
121.50
41.5
57.5
10 (plus 2.5 cm separated from the wall)
58
29.5
9.5
13.5
2000W
500W
750W
220-240V~
shelf
RF8E
RF10E
RF12E
Digital - 24hr / 7 Day Timer & Thermostat
8
10
12
73.5
89.5
105.5
17.5
21.5
25.5
1000W
1250W
1500W
minimum 15cm
minimum 25cm
RF14E
14
121.5
29.5
2000W
Closest
object to the
right end

Advertisement