PROPER USE AND INSTALLATION USING THIS MANUAL Congratulations on your choice of a Winco generator set. You must be sure your new engine generator set is: * Properly serviced before starting You have selected a high-quality, precision-engineered...
This engine generator set has been designed and manufac- b. Keep fuel containers out of reach of children. tured to allow safe, reliable performance. Poor maintenance, c. Do not smoke or use open flame near the generator set improper or careless use can result in potential deadly or fuel tank.
SPECIFICATIONS RESTRICTED USES 1. DO NOT remove from the base assembly. Removal of MODEL EC6010DR/R the generator from the base assembly or operating without the shock mounts installed may cause excessive Generator vibration and damage to the engine generator set.
Starting Electric Motors - Electric motors require much more current (amps) to start them than to run them. Trying to start a larger motor or higher code (ie. J or K) motor Some motors, particularly low cost split-phase motors, may result in damage to both the generator and the electric are very hard to start and require 5 to 7 times as much motor especially 120 volt motors.
1. Lubrication - Before starting the engine, fill the CAUTION: EQUIPMENT DAMAGE crankcase to the proper level with a good quality oil. The These electric start engines are NEGATIVE GROUND. recommended grade of oil and quantity of oil required is Use extreme caution when connecting the battery.
INITIAL START UP STARTING HINTS Use the following checklist to verify the correct preparation 1. Cold weather of the engine generator before starting. a. Use the proper oil for the temperature expected. On All Units Check: b. Use fresh winter grade fuel. Winter grade fuel is 1.
CAUTION: EQUIPMENT OVERLOAD LOAD vs. OUTPUT ************************************************************** Keep the generator load within the generator and Generator Frequency Generator voltage receptacle nameplate rating. Overloading may cause Load Speed (Hz) 120V 240V damage to the generator and/or the loads Applied* (RPM) Recpt. Recpt.
the 120/240 volt (series) connection. Use a 40 or 45 2. Checking the Oil Level: The oil level must always be Amp single pole breaker for the 120 volt only (parallel) checked before the engine is started. Take care to remove connection.
CLEANING —————————————————————————-- PROBLEM (SYMPTOMS) POSSIBLE CAUSES —————————————————————————— Remove dirt and debris with a cloth or brush. DO NOT use Won’t Start (electric) *Fouled fuel injector. high pressure spray to clean either the engine or the *Out of fuel. generator. This high pressure spray could contaminate *Dead battery.
To the extent permitted by law, any and all warranties, including those of merchantability and fitness for a particular purpose, are limited to 12 months from date of purchase. In no event is WINCO liable for incidental or consequential damages.