Appliance Data - Valor Black Beauty Radiant Installer's Manual

Black beauty radiant gas fire
Table of Contents

Advertisement

This appliance does not contain any component manufactured from asbestos or asbestos
related products.
The appliance data label is on the inner face of the back panel at the lower left-hand side.
It is visible when the outer case is removed.
Gas
Inlet Pressure
Gross Heat Input
Burner Test Pressure (Cold)
Gas Connection
Burner Injector
Pilot & Atmosphere Sensing Device
Ignition
Aeration
INSTALLER'S GUIDE
3 A P P L I A N C E D A T A
Max.
Min.
Upper
(Centre Radiant)
Lower
(Outer Radiants)
Page 4
Natural (G20)
20mbar
5.6kW (19,100Btu/h)
1.25kW (4,300Btu/h)
17.95+0.75mbar
(7.2+0.3in w.g.)
8mm pipe
Bray Cat. 16 Size 120
Bray Cat. 28 Size 250B
OPNG9093
Twin-spark Piezo-
electric integral with
gas tap
Non-adjustable