4 Parts Replacement
4.11 Replacing Leg Section
This section describes the procedure to replace the leg section.
4.11.1 Replacing Waste Fluid Bottle
NOTE
• Discharge waste fluid fully to replace the waste fluid bottle.
• Confirm that there remains no waste fluid in the waste fluid tube.
1. Initialize the waste fluid counter.
"5.11.1 Parameter Initialization Menu" p.5-47
2. Remove the side maintenance cover R.
"4.2.4 Removing Side Maintenance Cover R" p.4-11
3. Remove the connector to the level switch (waste fluid).
No.
1
2
4. Remove the waste fluid tube.
5. Loosen the cap of the waste fluid bottle.
Rev.-00
1
2
Connector to the level switch (waste fluid)
Cover stay RR
Part name
4-136