Yamaha 01v 96 Service Manual page 82

Digital mixing console
Hide thumbs Also See for 01v 96:
Table of Contents

Advertisement

01V96
4-4. WORD CLOCK IN and 2TR DIGITAL IN PLL
operation range
Parameters
Use System Two.
Inspect with STEREO OUT L/R
(XLR).
Select the WORD CLOCK as follows.
WORD CLOCK IN inspection: WC IN
2TR DIGITAL IN inspection: 2TR D
Input from CH1 (XLR).
A. 96kHz + 6% (101.76kHz)
Parameter
For WORD CLOCK IN inspection, set
the oscillator frequency setting to 96
kHz + 6%.For 2TR DIGITAL IN
inspection, set the System Two
frequency setting (Sample Rate) to 96
kHz +6%.
q Distortion ratio (for both WORD CLOCK IN and 2TR
DIGITAL IN)
Input frequency
Output level
1kHz
+22dBu
B. 44.1kHz - 10% (39.69kHz)
Parameter
For WORD CLOCK IN inspection, set
the oscillator frequency setting to 44.1
kHz -10 %. For 2TR DIGITAL IN
inspection, set the System Two
frequency setting (Sample Rate) to
44.1 kHz - 10%.
q Distortion ratio (for both WORD CLOCK IN, 2TR
DIGITAL IN)
Input frequency
Output level
1kHz
+22dBu
5. Jitter measurement
Parameters
Use System Two.
Inspect with 2TR DIGITAL OUT.
5-1. WORD CLOCK INT
Parameter
Select the value of the WORD
CLOCK according to the following
table.
q Jitter
WORD CLOCK
INT 44.1kHz
INT 48kHz
INT 88.2kHz
INT 96kHz
5-2. WORD CLOCK EXT
Parameters
Select the WORD CLOCK as follows.
WORD CLOCK IN inspection: WC IN
2TR DIGITAL IN inspection: 2TR D
82
Permissible range
0.01% or below
Permissible range
0.01% or below
Select Sec, PK.
Select BW: 700 Hz to 100kHz.
Permitted range
5nsec or below
5nsec or below
5nsec or below
5nsec or below
For WORD CLOCK IN inspection,
select the value of the frequency
setting according to the table below.
For 2TR DIGITAL IN inspection, set
the System Two frequency setting
(Sample Rate) according to the table
below.
q Jitter (both WORD CLOCK IN and 2TR DIGITAL IN)
WORD CLOCK
44.1kHz
48kHz
88.2kHz
96kHz
6. Issuing sound
Check the following items by listening.
ANALOG INPUT, ANALOG OUTPUT
CH1 (XLR), CH9 (XLR), CH16 (PHONE) →
Inspect with STEREO OUT L/R (XLR).
EEFFECT function (DSP6 operation check)
Parameters
"Sound scene data": Use the file
name "JADE_01".
WORD CLOCK: INT48kHz
Input the music signal from ANALOG
INPUT CH1, recall scenes in order
from Scene 1 to Scene 4, and adjust
the [GAIN] knob so that the
STEREO METER OVER does not
light up for any scene.
Inspection :
Recall Scene 1 (REVERB) and check
the signal with the headphones for at
least 15 seconds.
Judgment standard 1: The EFFECT sounds must
be output.
Judgment standard 2: The output must not include
any noise.
In the same manner, recall and inspect Scenes 2
through 16.
The Effect functions for Scenes 2 through 14 work
as follows.
Permitted range
10nsec below
10nsec below
10nsec below
10nsec below

Hide quick links: