Fault
Green
LED
illumi-
nates.
Yellow
LED
illumi-
nates.
Yellow
LED
flas-
hes.
Red
LED
illumina-
tes.
Red
LED
flashes.
Red
LED
illumina-
tes.
NEPTUNE PE-DE_en_Ver.1.0_October 2010

Troubleshooting

Cause
Machine ready to opeate.
All LEDs flash once be-
fore the motor is turned
on.
Fuel level is low.
Alto Anti Stone level is
low.
Pump oil level is low.
Service interval: service
due in 20 hours.
Service interval elapsed.
Jetwash Direct ltd
Remedy
Refill fuel. "Cold water"
mode is possible.
Refill Alto Anti Stone.
"Hot water" and "Cold
water" mode is possible.
Refill pump oil (Chapter
F.1.3). The burner and
motor are cut out. The
green
LED
extinguis-
hes.
Service
the
machine.
"Hot water" and "Cold
water" mode is possible.
Service the machine.
"Hot water" and "Cold
water" mode is possible.