Remove the outer top cover and mount the
lifting tool over the two coil ends and fix it
with the nuts. Dismount the 4 nuts
"Arrows"and hook up the crane and lift out
the coil.

Burner Unit.

1.
Fuel solenoid
2.
Fuel pump
3.
Burner motor
4.
Burner housing
5.
Fuel filter
6.
Fan
7.
Fan cover
NEPTUNE PE-DE_en_Ver.1.0_October 2010
Service / Repair
Burner fan and fuel pump.
Jetwash Direct ltd
Check the flame tu-
3
be marked with X
4
and Y. It is important
2
5
4
that they are solid
6
and complete.
7
Y is a part of the coil
8 and cannot be se-
parated.
X
8
Clean the coil.
Y
9
9
10
1
2
3
4
5
Clean up deposits and
change the isolation if
needed.
6
7
F
Boiler
9
60