Maintenance / Troubleshooting
Fault
Pressure drop
Pressure fl uctuations
The motor does not start when
the cleaner is switched on
Recycling the cleaner
Guarantee
Original Operating Instructions
Cause
>
Air in the system
>
High pressure nozzle blocked
worn
>
Pressure control on the spray
pipe is not set correctly
>
Detergent tank empty
>
Pump draws in air (only pos-
sible in suction mode)
>
Lack of water
>
Water inlet hose is too long
or its cross-section too small
>
Lack of water caused by
blocked water fi lter
>
Lack of water because max.
permissible suction height
has not been heeded
>
The plug is not inserted pro
perly, i.e. there is no current
>
The mains fuse is switched
off
Make the old cleaner un-
usable immediately.
1. Unplug the cleaner and cut
the power cord.
Do not discard of electrical ap-
pliances with household waste.
Our general conditions of busi-
ness are applicable with regard
to the guarantee. Subject to
change as a result of technical
advances.
Remedy
Vent the system by operat-
ing the spray gun several
times at short intervals.
If necessary, operate the
cleaner for a short time
without the high-pressure
hose connected.
Clean/replace the high
pressure nozzle
Set the required working
pressure
Top up detergent tank or
set detergent metering to
"0"
Check that the suction set
is air-tight
Open water tap
Use specifi ed water inlet
hose
Clean the water fi lter in the
water connection (never
work without water fi lter)
See instructions
Check the plug, lead and
switch and if necessary
have them replaced by a
trained electrician
Switch on the mains fuse
As specified in European Direc-
tive 2012/19/EU on old electri-
cal and electronic appliances,
used electrical goods must be
collected separately and recy-
cled ecologically. Contact your
local authorities or your nearest
dealer for further information.